52 kg / 115 lb. / 520 L Models
Voltage
Cycle
Phase
Wire
Total
power
(kW)
Hot and
Cold Wa-
ter Inlet
Valves
Full Load
Amps
Electric
Heat
Full Load
Amps
(Electric
Heating
kW)
Fuse (A)
200-240
50-60
1
2 (L1, L2 or
L1, N)
4.1
25
N/A
32
200-240
50-60
3
3 (L1, L2,
L3)
4.1
16.5
N/A
20
200-240
50-60
3
3 (L1, L2,
L3)
43
N/A
109 (40.6)
125
380-415
50-60
3
3 (L1, L2,
L3)
4.1
9.6
N/A
16
440-480
50-60
3
3 (L1, L2,
L3)
4.1
9.6
N/A
16
380-415
50-60
3
3 (L1, L2,
L3)
43
N/A
62.9 (40.6)
80
440-480
50-60
3
3 (L1, L2,
L3)
43
N/A
81.5 (40.6)
100
Table 25
Steam Requirements (Steam Heat Op-
tion Only)
WARNING
Hot Surfaces. Will cause severe burns. Turn steam
off and allow steam pipes, connections and compo-
nents to cool before touching.
W505
For machines equipped with optional steam heat, install piping in
accordance with approved commercial steam practices. Steam re-
quirements are shown in
Table 26
.
Specification
Model
Requirement
Steam inlet con-
nection size, in.
BSP
8 kg / 20 lb. / 80 L
- 28 kg / 70 lb. /
280 L
1/2
Steam inlet con-
nection size, in.
BSP
35 kg / 80 lb. /
332 L - 52 kg /
115 lb. / 520 L
3/4
Steam pressure,
PSI [bar]
All
15-116 [1-8]
Table 26
IMPORTANT: It is necessary to insert a filter with per-
meability up to 0.0118 in. [300 µm] in front of the steam
valve. Dirt larger than 0.0118 in. [300 µm] may damage
the steam valve and cause leaks.
IMPORTANT: Failure to install the customer supplied
steam filter may void the warranty.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
50
Part No. D1634ENR4