Voltage
Cycle
Phase
Wire
Total
power
(kW)
Hot and
Cold Wa-
ter Inlet
Valves
Full Load
Amps
Electric
Heat
Full Load
Amps
(Electric
Heating
kW)
Fuse (A)
380-415
50-60
3
3 (L1, L2,
L3)
1.6
3.7
N/A
10
440-480
50-60
3
3 (L1, L2,
L3)
1.6
3.7
N/A
10
380-415
50-60
3
3 (L1, L2,
L3)
23.2
N/A
38 (21.9)
40
440-480
50-60
3
3 (L1, L2,
L3)
23.2
N/A
35 (21.9)
32
Table 23
35 kg / 80 lb. / 332 L Models
Voltage
Cycle
Phase
Wire
Total
power
(kW)
Hot and
Cold Wa-
ter Inlet
Valves
Full Load
Amps
Electric
Heat
Full Load
Amps
(Electric
Heating
kW)
Fuse (A)
200-240
50-60
1
2 (L1, L2 or
L1, N)
2.3
16.2
N/A
20
200-240
50-60
3
3 (L1, L2,
L3)
28.5
N/A
76.8 (27)
80
380-415 + N
50-60
3
4 (L1, L2,
L3, N)
28.5
N/A
48.1 (27)
63
380-415
50-60
3
3 (L1, L2,
L3, N)
2.3
8.2
N/A
16
440-480
50-60
3
3 (L1, L2,
L3)
2.3
8.2
N/A
16
380-415
50-60
3
3 (L1, L2,
L3)
28.5
N/A
43.5 (27)
50
440-480
50-60
3
3 (L1, L2,
L3)
28.5
N/A
51.9 (27)
63
Table 24
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
49
Part No. D1634ENR4
Summary of Contents for WMA103E ARIES