NOTE: The maximum length of a 4 in. [102 mm] diame-
ter flexible metal duct must not exceed 7.87 ft. [2.4 m] ,
as required to meet UL2158, clause 7.3.2.A.
Gas Dryers - Connect Gas Supply Pipe
WARNING
To reduce the risk of gas leaks, fire or explosion:
• The dryer must be connected to the type of gas
as shown on nameplate located in the door re-
cess.
• Use a new flexible stainless steel connector.
• Use pipe joint compound insoluble in L.P. (Lique-
fied Petroleum) Gas, or Teflon tape, on all pipe
threads.
• Purge air and sediment from gas supply line be-
fore connecting it to the dryer. Before tightening
the connection, purge remaining air from gas line
to dryer until odor of gas is detected. This step is
required to prevent gas valve contamination.
• Do not use an open flame to check for gas leaks.
Use a non-corrosive leak detection fluid.
• Any disassembly requiring the use of tools must
be performed by a suitably qualified service per-
son.
W316
1. Make certain your dryer is equipped for use with the type of
gas in your laundry room. Dryer is equipped at the factory for
Natural Gas with a 3/8 inch NPT gas connection.
NOTE: The gas service to a gas dryer must conform
with the local codes and ordinances, or in the ab-
sence of local codes and ordinances, with the latest
edition of the National Fuel Gas Code ANSI Z223.1/
NFPA 54 or the CAN/CSA-B149.1 Natural Gas and
Propane Installation Code.
Natural Gas, 1000 Btu/ft
3
[37.3 MJ/m
3
] , service must be sup-
plied at minimum 5.0 inch water column pressure to maximum
10.5 inch water column pressure.
For proper operation at altitudes above 3000 feet [915 m] the nat-
ural gas valve spud orifice size must be reduced to ensure com-
plete combustion. Refer to
Natural Gas Altitude Adjustments
Altitude
Orifice Size
Part
No.
feet [m]
No.
inches [mm]
3000 [915]
43
0.0890 [2.26]
D503778
6000 [1830]
44
0.0860 [2.18]
58719
8000 [2440]
45
0.0820 [2.08]
D503779
9000 [2740]
46
0.0810 [2.06]
D503780
10,000 [3050]
47
0.0785 [1.99]
D503781
Table 3
2. Remove the shipping cap from the gas connection at the rear
of the dryer. Make sure you do not damage the pipe threads
when removing the cap.
3. Connect to gas supply pipe using thread sealant or Teflon
tape. Torque 90 - 175 inch-pounds [10.2 - 19.7 Nm] .
NOTE: The connection of gas supply to the appli-
ance shall be made with a flexible hose suitable for
the appliance category in accordance with national
installation regulations of the country of destina-
tion. If in doubt contact the dryer distributor or man-
ufacturer.
NOTE: When connecting to a gas line, an equipment
shut-off valve in accordance with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 and the Natural
Gas and Propane Installation Code, CSA B149.1
must be installed within 6 feet [1.8 m] of the dryer.
An 1/8 in. NPT pipe plug must be installed as shown
for checking inlet pressure. Refer to
Starting Serial No. 1908000001, the following must be furnished
and installed by the customer for the gas service line to dryer:
Union at gas supply connection (listed to ANSI Z21.24 and CSA
6.10).
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
15
Part No. D518518ENR1