40 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
P
Standard
380–415
50/60
3
3
3
15
14
2.5
Electric
Heat
25
30
10
6.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 27
60 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
F and V-Speed Models
(unless otherwise noted)
X (F-speed)
200–208
50/60
1/3
2/3
9/6
15
14
2.5
220-240
X (V-speed)
200-208
50/60
1/3
2/3
10/6
15
14
2.5
220-240
Q
Standard
200-208
50/60
3
3
6
15
14
2.5
Electric
Heat
220-240
43
50
8
10.0
N
Standard
440-480
50/60
3
3
4
15
14
2.5
Electric
Heat
22
30
10
6.0
P
Standard
380-415
50/60
3
3
4
15
14
2.5
Electric
Heat
25
30
10
6.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 28
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
54
Part No. F8429301ENR15
Summary of Contents for SCB040GNF