Electronic Control Troubleshooting
40. Will Not Heat – Electric
T034D
Single and stacked units with single and three
phase supply.
Note: Tests are conducted with unit running
and calling for heat.
All voltage checks are referenced to
transformer neutral.
Correct wiring
between FS-2 and
COM of lint drawer.
Is there voltage on
FS-2 of EDC control?
Is there voltage
on FS-1 of
EDC control?
Correct wiring
between COM of
airflow switch and
FS-1 of EDC
control.
Is there voltage on
COM of airflow
switch?
Check for proper
function of airflow
switch and replace
if necessary.
Is there voltage at
N.C. terminal of
airflow switch?
Correct wiring
between terminal 7
on motor control
relay and N.C.
terminal on airflow
switch.
Is there voltage on
terminal 7 of motor
control relay?
Replace motor
control relay.
Is there voltage at
terminal 4 of motor
control relay?
Correct wiring
between terminal
3 of fan motor
centrifugal switch
and terminal 4 of
motor control relay.
Is there voltage on
terminal 3 of fan
motor centrifugal
switch?
Replace fan motor.
Is there voltage at
terminal 5 of fan
motor centrifugal
switch?
Correct wiring
between cabinet
limit and terminal
5 of fan motor
centrifugal switch.
Is there voltage to the
input side of the
cabinet limit?
Replace cabinet
limit.
Is there voltage at the
output of the cabinet
limit?
Correct wiring
between stove limit
and cabinet limit.
Is there voltage to the
input side of the stove
limit?
NO
YES
Is the
thermistor
operational?
Replace EDC
control.
Replace
thermistor.
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
NO
YES
YES
NO
NO
YES
YES
NO
NO
YES
Continued on next
page.
T034D