Electronic Control Troubleshooting
39. Will Not Heat – Electric – Manual Timer
T054D
NOTE: The following tests are conducted with
the heat timer in the "ON" position with the
machine running and calling for heat. Voltage
checks are referenced to transformer neutral.
Is there voltage across
terminals 1 & 6 of
the temp control bd?
Is there voltage across
terminals 5 & 6 of
the temp control bd?
YES
NO
voltage at
airflow switch
N.C. terminal to
transformer
NO
Replace inoperative
switch or correct
airflow vane operation.
NO
YES
Is there voltage at
terminal 6 on CR1 to
transformer neutral?
NO
Correct wiring between
airflow switch and
terminal 6 on CR1.
Is there voltage from
terminal 4 on CR1 to
transformer neutral?
Replace CR1.
YES
NO
YES
Is there voltage from
terminal 6 on CR2 to
transformer neutral?
Correct wiring
between terminal 6
on CR2 to terminal
4 on CR1.
NO
YES
Is there voltage from
terminal 4 on CR2 to
transformer neutral?
Replace CR2.
NO
YES
Correct wiring
between CR2
terminal 4 &
terminal 1 on
temp control
board.
Is the thermistor
shorted or open?
NO
YES
Replace thermistor.
Replace the
temperature
control board.
YES
CONTINUED
ON NEXT
PAGE
Is unit equipped with
time delay board?
NO
YES
Is there
voltage to
terminal 3 of
fan motor?
NO
YES
Correct wiring
between fan motor
terminal 3 and
CR1 terminal 4.
Is there voltage
at terminal 3 & 5
of fan motor?
Replace fan motor.
YES
NO
Correct wiring
between motor
terminal 5 and
temp control
board terminal 1.
With and without time delay board.
Single and stacked units. Single and
three phase power supply.
Is temperature
selection switch
shorted or open?
Replace selection
switch.
YES
NO
T054D
Is there
neutral?