802748
13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
General Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
(3) Place a small flathead screwdriver under
right side of tension spring and lift up.
Refer to
Figure 5
.
(4) Use screwdriver to move spring
approximately 3 mm to left.
(5) Lift spring over left tab. Refer to
Figure 5
.
(6) Rotate spring clockwise, 40 to 60 degrees,
until it is free from right tabs. Refer to
Figure 6
.
(7) Use screwdriver to remove spring from
center tab. Refer to
Figure 6
.
(8) Lift spring, with attached clip, off drop.
(9) Remove clip from spring. Refer to
Figure 7
.
(10) Attach clip to new tension spring, Part No.
209/00598/02.
(11) Place clip, installed on spring, in slot on
coin drop. Refer to
Figure 8
.
Figure 5
Figure 6
MIX2B
Small Flathead
Screwdriver
Right Side of
Tension Spring
Left Tab
MIX3B
Tabs
Center Tab
Figure 7
Figure 8
MIX4B
Clip
MIX8B
Slot