Programming
26
F232087
Cycle Segment Charts
Segment 1 (Prewash)
Display
Instructions
Use the Up or Down key to change. Press the Start key to enter or advance.
PrE
PrEU or FLUS
Select either “PREU” (regular prewash) or “FLUS” (flush)
00 or 02 to 30
Select segment time: 02 to 30 minutes (00 to skip segment)
HFIL, CFIL, or bFIL Select “HFIL” (hot fill), “CFIL” (cold fill), or “bFIL” (warm fill)
LOLE or HILE
Select fill level: “LOLE” (low), or “HILE” (high) water level
SUP0–SUP7
Select supply 0–7 (0 for no supply)*
00°F, 75°F–200°F
00°C, 25°C–93°C
Select temperature: 75 to 200°F or 25 to 93°C (00 for no heat)**
SPIn (flashed for one second)
tInE (flashed for one second)
00 or 30 to 120
Select time for spin: 30 to 120 seconds (00 for no spin)
*Supply 4 and Supply 7 are available only if Supply 4 is enabled in the SETUP options.
**This is displayed only if auxiliary heat is enabled in the SETUP options.