Dimensions and Specifications

M412060

10

Specifications

Conversion Table 

Cabinet Finish:

Electrostatically applied thermosetting polyester

Cylinder Size:

30 in x 25 in (76.2 x 63.5 cm) perforated galvanized steel with three baffles

Air Outlet:

6 in (15.24 cm)

Total Dry Weight Capacity:

60 lbs. (27.2 kg) both cylinders

Width

31-5/8 in (80.3 cm)

Depth

46-1/2 in (118 cm)

Height

72-1/4 in (183.5 cm)

Motor:

1/2 H.P., lifetime lubricated, internal overload protected

Electrical Specifications:

120/60/1 (17.3 Amp) 2-wire grounded system (Line 1, Neutral & Ground)

208-240/60/1 (10 Amp) 3-wire grounded system (Line 1 & 2, Neutral & 
Ground)

120/50/1 (17.3 Amp) 2-wire grounded system (Line 1, Neutral & Ground)

240/50/1 (10 Amp) 2-wire grounded system (Line 1, Neutral & Ground)

220/60/1 (10 Amp) 2-wire grounded system (Line 1, Neutral & Ground)

Energy Data: 

63,000 BTU per hour (per pocket - 15,876 Kcal)

Types of Gas:

Factory equipped with Natural Gas (6-1/2 ± 1-1/2 inches water column line 
pressure); Liquefied Petroleum gas (11 ± .3 inches water column line pressure); 
Hong Kong Town Gas (High and Low Pressure), or Korean LNG.

Gas Connection:

 1/2 in (1.27 cm) supply line reduced to a 3/8 in (.95 cm) N.P.T. connection

Air Flow:

375 C.F.M. (177 liters/sec.)

Approx. Net Weight:

722 Pounds (310.5 kg) 

Multiply By 

To 

Obtain 

BTU .252 

Kcal 

BTU 1055 

Joules 

Inch 2.54 

Centimeters 

Inches W.C. 

. 036 

Pounds/sq. in

Pounds/sq. in 

. 06895 

Bars 

Pounds/sq. in 

. 070 

kg/sq. cm. 

Pounds (lbs.) 

.454 

Kilograms 

Boiler Horsepower 

33,479 

BTU /lb. 

Boiler Horsepower 

34.5 

Ibs. Steam/hr. 

Inches W.C. 

. 249 

kPa 

Summary of Contents for Stacked Drying Tumbler

Page 1: ...on Operation Maintenance Stacked Drying Tumbler Models with Electronic Control Part No M412060R2 May 2006 Keep These Instructions For Future Reference If this tumbler changes ownership be sure this ma...

Page 2: ......

Page 3: ...taller service agency or the gas supplier W052 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W053 WARNING POUR VOTRE...

Page 4: ...models are not certified in Australia NOTE The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be under...

Page 5: ...ion 11 Materials Required 11 Facilities Required 11 Layout 11 Floor 11 Shipping Braces 11 Venting 11 Individual Venting 12 Combined Exhaust Manifold Venting 12 Collector Venting 12 Individual Exhaust...

Page 6: ...COPY or TRANSMIT 4 M412060 Preventive Maintenance Instructions 33 Daily 33 Lint Removal 33 Monthly 33 Lubrication 33 Lint Removal 33 Every Six Months 35 Lint Removal and Cylinder Belt Inspection 35 D...

Page 7: ...talled operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you to substance...

Page 8: ...he cylinder with a damp cloth to remove particles of fiberglass 24 Always follow the fabric care instructions supplied by the garment manufacturer 25 Never operate the tumbler with any guards and or p...

Page 9: ...l numbers will be found on the nameplate as shown Replacement Parts Information If replacement parts are required contact the source from whom you purchased your tumbler or contact the Ripon Service P...

Page 10: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 8 Notes...

Page 11: ...for service access Sides 0 in 0 cm permitted 31 5 8 in 80 3 cm 31 5 8 in 80 3 cm 20 3 4 in 62 7 cm 33 3 4 in 85 7 cm 42 5 8 in 108 3 cm 43 1 2 in 110 5 cm 46 1 2 in 118 1 cm 28 1 4 in 71 8 cm 4 5 32 i...

Page 12: ...50 1 17 3 Amp 2 wire grounded system Line 1 Neutral Ground 240 50 1 10 Amp 2 wire grounded system Line 1 Neutral Ground 220 60 1 10 Amp 2 wire grounded system Line 1 Neutral Ground Energy Data 63 000...

Page 13: ...er square foot 488 kg square meter Floor covering materials such as carpeting or tile should be removed Shipping Braces To facilitate installation the shipping braces located on the lower left and rig...

Page 14: ...y to the outdoors a main collector duct may be used if it is sized according to Figure 4 These illustrations indicate minimum diameters and should be increased if the collector length exceeds 20 feet...

Page 15: ...in 76 2 cm Minimum Clearance Figure 2 2 in 5 1 cm Minimum Clearance 30 in 76 2 cm Minimum Clearance 2 in 5 1 cm Minimum Clearance 2 in 5 1 cm Minimum Clearance No Screen or Cap Wall Air Out Inspectio...

Page 16: ...fold Construction Figure 3 TMB2155N 10 in 25 4 cm Inside Diameter 17 50 in 44 5 cm 36 10 in 91 7 cm 2 in 5 1 cm TYP Standard Stove Pipe Crimp 6 in 15 2 cm Inside Diameter 2 Places Rivet to Duct 8 Rive...

Page 17: ...tted for First 4 in 10 2 cm 12 in 30 5 cm Minimum Clearance 0 in Clearance Permitted for First 4 in 10 2 cm 2 in 5 1 cm Minimum Clearance No Screen or Cap Wall NOTE Maximum length of exhaust duct is 1...

Page 18: ...unscrew the four shipping capscrews one at each corner and lift the tumbler from the skid The leveling legs will be in a bag inside the cylinder Screw the four leveling legs into the level adjusting...

Page 19: ...e Figure 5 TMB2157N Clearance of tumbler cabinet from combustible construction must be a minimum of 12 inches 30 5 cm at top W647 WARNING NOTE Shaded areas indicate adjacent structure 0 in Clearance P...

Page 20: ...st be done by installing a one inch 2 54 cm pipe gas loop as shown in Figures 8 and 9 Before connecting the gas piping to the tumbler make certain gas service is the same as that specified on the seri...

Page 21: ...e compound resistant to actions of L P gas on all pipe threads To reduce the risk of fire or explosion The tumbler and its individual shut off valve must be disconnected from the gas supply piping sys...

Page 22: ...0 1 25 40 1 25 40 1 25 31 75 1 25 31 75 1 5 38 10 1 5 38 10 2 50 80 2 50 80 2 50 80 2 50 80 2 50 80 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 3 76 20 3 76 20 3 76 20 3 76 2...

Page 23: ...mblers Gas Line Pressure Tap IMPORTANT Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers connected to single gas service Other gas using appliances should be c...

Page 24: ...efer to Figure 10 IMPORTANT Do not connect the tumbler to any voltage or current other than that specified on the tumbler serial plate Heat Source Electrical Specs Wires Required and Terminal Block Co...

Page 25: ...s of the terminal block L1 and L2 or L1 and N If the electrical service is 120 Volt connect the neutral wire to NEUTRAL The ground wire must be connected to the green ground screw located in the junct...

Page 26: ...THE GAS LINE TO EITHER OF THE TUMBLERS IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER It will first be necessary to convert the gas burner orifice and gas valve Appropriate conver...

Page 27: ...does not light open and close loading door again and restart the ignition cycle IMPORTANT The Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds...

Page 28: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 26 Notes...

Page 29: ...e tab on the door should contact the switch plunger and depress it enough to close the switch with an audible click Refer to Figure 13 3 If tab does not depress the switch plunger enough to operate th...

Page 30: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Adjustments M412060 28 Figure 13 Door Tab TMB2163N Door Switch Front Serial Plate Location Figure 14 TMB2164N...

Page 31: ...4 inches 45 to 57 mm If it does not adjust the loading door interlock Refer to the appropriate paragraph in the Adjustments section of this manual 5 Start the tumbler and check the burner flame 6 Loa...

Page 32: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 30 Notes...

Page 33: ...close lint drawer will result in the tumbler not starting 3 Open the loading door and load the cylinder with laundry The unit is designed for a 30 pound cotton load dry maximum load DO NOT overload O...

Page 34: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 32 Notes...

Page 35: ...r ensuring a tight fit and lock IMPORTANT Failure to lock lint drawer will result in the tumbler not starting Monthly Lubrication Motor bearings fan bearings cylinder bearings and cylinder roller bear...

Page 36: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Preventive Maintenance Instructions M412060 34 Figure 15 TMB2165N...

Page 37: ...e service replacement 4 Inspect the belt tensioning idler assembly The idler arm should move freely with considerable belt spring tension approximately 40 pounds and should not bind in any position be...

Page 38: ...k and clean steam coils Steam Models Only Clean exhaust ducts Check flow of combustion air Check flow of ventilation air Check belt tension Check chain tension Six Month Maintenance DATES Check for lo...

Reviews: