3.   Use a strain relief and insert end of power cord through power

supply hole.

D696I_SVG

Figure 14

4.   Use the three screws from the accessories bag to attach the

power cord wires to the terminal block. Refer to 

Figure 15 

.

3-Wire Connection

DRY2508N_SVG

4

3

2

1

1.  

"L1" Terminal

2.  

Neutral Terminal

3.  

"L2" Terminal

4.  

Earth/Ground to Bulkhead

Figure 15

5.   Using a screwdriver, tighten all screws firmly.

IMPORTANT: Failure to tighten these screws firmly
may result in wire failure at the terminal block.

6.   Secure the strain relief to the power cord, or wires, where they

enter the dryer cabinet.

7.   Check the continuity of the earth/ground connection before

plugging the cord into an outlet. Use an acceptable indicating
device connected to the center earth/ground pin of the plug
and the green screw on the back of the cabinet.

8.   Reinstall access cover and screw.

 Connecting Power Cord with Four-Wire Plug

NOTE: Four-wire cord is required for new branch-cir-
cuit installations, mobile homes or where codes do not
permit grounding through neutral.

DRY2016N_SVG

7

7

7

7

6

3

2

1

4

5

1.  

Typical Four-Wire Receptacle

2.  

Power Cord – Not Supplied with Dryer

3.  

Strain Relief Nut

4.  

Strain Relief

5.  

0 V.A.C.

6.  

240 ± 12 V.A.C.

7.  

120 ± 12 V.A.C.

Figure 16

1.   Disconnect power to dryer.
2.   Remove access cover from rear of dryer.

DRY2467N_SVG

Figure 17

3.   Remove earth/ground screw from earth/ground to neutral wire

and save for use in Step 5. Earth/ground to neutral wire will
be attached to the neutral terminal in Step 6.

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  18

  Part No. 807638EN

Summary of Contents for Speed Queen SF7003WE

Page 1: ...Dryers Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine w...

Page 2: ......

Page 3: ...er user smells gas The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use WARNING Installation of unit must...

Page 4: ...er or gas fitter This appliance must be installed with a 910 mm 36 inch long flexible gas connector A T Handle type gas shut off valve must be installed in the gas supply line to this appliance This a...

Page 5: ...mation 16 Connecting Power Cord with Three Wire Plug 16 Connecting Power Cord with Four Wire Plug 18 Connect Dryer Exhaust System 20 Exhaust Direction 21 Exhaust System 21 Position and Level the Unit...

Page 6: ...n E 610 mm 24 in F 203 mm 8 in G 391 mm 15 4 in H 938 mm 36 9 in I 371 mm 14 6 in J 813 mm 32 in K 683 mm 26 875 in L 1184 mm 46 62 in M 1986 mm 78 17 in N 52 mm 2 04 in O 704 mm 27 73 in P with door...

Page 7: ...3 8 in NPT Gas Connection A 1678 mm 66 06 in B 1447 mm 56 97 in C 597 mm 23 5 in D 213 mm 8 375 in E 610 mm 24 in F 203 mm 8 in G 391 mm 15 4 in H 59 mm 2 3 in I 938 mm 36 9 in J 371 mm 14 6 in K 114...

Page 8: ...333 mm 13 1 in With leveling legs turned into base For ADA compliance turn legs out from base 0 5 inches NOTE Exhaust openings are 102 mm 4 inch metal ducting Dimensions Copyright Alliance Laundry Sys...

Page 9: ...l hoses are required for installation Order 807239 Hose Kit if needed Kit includes two fill hoses color coded for hot and cold water If using any other hoses follow these requirements Hoses must be ne...

Page 10: ...lation Area Move unit so that it is within 1 2 meters 4 feet of the desired area of installation CAUTION Washer and dryer are not designed to be operated as separated side by side units W187 The stack...

Page 11: ...rear shipping bolt holes FLW2358N_SVG Figure 5 7 Replace front access panel 8 Save all shipping materials They must be reinstalled any time washer is moved more than four feet IMPORTANT Do not lift o...

Page 12: ...nto the water faucets until they are finger tight Use the red color coded hose for the hot water connection and the blue color coded hose for the cold water connection 4 Then using a pliers screw appr...

Page 13: ...and place around standpipe and drain hose Refer to Figure 8 a Insert the end of the beaded strap into the larger hole found on the end of the strap b Tighten to desired fit c Lock strap in place by p...

Page 14: ...flame to check for gas leaks Use a non corrosive leak detection fluid Any disassembly requiring the use of tools must be performed by a suitably qualified service per son W316 1 Make certain your dry...

Page 15: ...following must be furnished and installed by the customer for the gas service line to dryer Union at gas supply connection listed to ANSI Z21 24 and CSA 6 10 D233I_SVG 2 3 4 1 5 1 New Stainless Steel...

Page 16: ...phase circuit AC alternating current circuit fused at 30 Amperes the circuit must be fused on both sides of the line Electrical service for the dryer should be of maximum rated voltage 208 or 240 Vol...

Page 17: ...ce Entrance Switch Box Refer to NOTE above 8 30 Ampere Fuses or Circuit Breaker 9 Neutral Wire 10 Metallic or Non Metallic Sheathed Cable Copper Wire Only 11 Power Cord Not supplied with dryer 12 Neut...

Page 18: ...able indicating device connected to the center earth ground pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord with Four Wire Plug...

Page 19: ...re to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along with the white wire to the neutral center te...

Page 20: ...t Figure 21 DO NOT use plastic thin foil or type B ducting Rigid metal duct is recommended Locate dryer so exhaust duct is as short as possible Be certain old exhaust ducts are cleaned before installi...

Page 21: ...or bottom can be accomplish ed by installing a Directional Exhaust Kit 528P3 available as optional equipment at extra cost Exhaust System For best drying results recommended maximum length of ex haust...

Page 22: ...andle in the transportation of the unit may cause damage to the dispenser or doors 2 Place unit in position on a solid sturdy and level floor Instal ling the unit on any type of carpeting soft tile or...

Page 23: ...Remove four hinge attaching screws D675I_SVG Figure 23 2 Remove all nine screws D272P_SVG Figure 24 3 Pull bottom of door liner out then pull down removing door liner from door panel DRY1916N_SVG B A...

Page 24: ...osite side of door opening D317S_SVG Figure 30 9 Reinstall four hinge attaching screws removed in Step 1 D606I_SVG Figure 31 Wipe Out Inside of Washer and Dryer Drum IMPORTANT Prior to first wash use...

Page 25: ...he customer s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer W521 When plugging in the dryer DO NOT o...

Page 26: ...ground prong from this plug W823 WARNING Improper connection of the equipment earth ground conductor can result in a risk of electric shock Check with a qualified electrician or service person if you...

Page 27: ...hould be plugged directly into a polarized three slot effective earth ground receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 36 to determine correct polarity of the wall...

Page 28: ...with a three prong earth ground plug for your protection against shock haz ard and should be plugged directly into a protective earth ground three prong receptacle Do not cut or remove the earth groun...

Page 29: ...m blue flame A lazy yellow tipped flame indicates lack of air A harsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the ai...

Page 30: ...nside of Washer and Dryer Drums SWD1054N_SVG CHECK CHECK 4 Connect Drain Hose to Drain Receptacle SWD1010N_SVG1 10 Plug In Washer and Dryer DRY2669N_SVG CHECK CHECK 5 GAS ONLY Connect Gas Supply Pipe...

Reviews: