Shorted Output
Error Code
Gas Valve 2 Output (GV2)
17
Table 16
Shorted Thermistor Error
This error will be set when the I/O board senses a temperature
greater than 210°F [99°C] and the motor is active. Once the cycle
has ended and the error is active, the error will not be allowed to
be cleared until the temperature reading is less than 210°F
[99°C]. When this error occurs, the display will show "Shorted
Thermistor Error". If this error occurs during a cycle, the machine
will go to cool down.
Stove Limit Cycles
Depending on the configuration, machines either have 1 or 2 lim-
it thermostats monitoring the stove temperature. If at any point
during the cycle, the stove temperature exceeds the limit tempera-
ture and one of these limits opens, the heat will be turned off until
the limit is reset. If the Display Limit Cycles parameter is ena-
bled, an error will be set. These errors will be treated as end of
cycle errors. If the first limit opens causing an error, the display
will show "Stove Limit 1 Cycle", while the second limit opening
will display "Stove Limit 2 Cycle".
The control will increment the individual audit counter only once
per cycle. The error will only be displayed for the two (2) minute
pause between cycles.
System Integrity Error
This error occurs if a
SCI Communication Error (Fatal)
happens
on the drive or output board. When the error sets, drive or output
board stops communication with the control. The output board
displays the error by flashing LEDs on and off. The machine
must be powered down to clear the error.
Error Description
Number of LED Flashes
CPU Error
1
SFR Error
2
ROM Error
3
RAM Error
4
Stack Error
5
RAM Buffer and Empty Error
6
Software Watchdog Error
7
Slow Monitoring Error
8
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
62
Part No. 70600001ENR6