42
53273
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
51. FRONT BULKHEAD ASSEMBLY
a. Remove front panel. Refer to Paragraph 13.
b. Remove screws holding bulkhead to cabinet
and lift assembly out of slots in cabinet. Refer
to Figure 33.
c. Remove cylinder glides. Refer to Figure 34.
NOTE: Front air duct will be removed with the
bulkhead unless previously removed in Paragraph
44.
TO REMOVE FRONT CYLINDER SEAL
d. Unhook spring from seal strap. Refer to
IMPORTANT: When installing seal, tape it to the
bulkhead in several places to hold in position while
replacing seal strap and spring. Remove tape after
strap and seal are in place. Seal must be under strap
securely and be folded back under flanged edge
around entire bulkhead. Strap must be installed
with cupped surface down against the seal to hold
the felt seal more firmly in place on the bulkhead.
Also the seal can be adhered to the bulkhead using
Locktite No. 416 (obtain locally). This is
accomplished by applying a bead of Locktite No.
416 around the entire flanged area where the felt
seal contacts the bulkhead.
52. CYLINDER BELT
a. Remove front panel. Refer to Paragraph 13.
b. Disengage belt from motor and idler pulleys.
c. Remove front bulkhead. Refer to Paragraph 51.
d. Remove belt.
NOTE: When reassembling, belt must be properly
positioned around cylinder and on motor and idler
pulleys. Refer to Figure 35.
Figure 33
DRY858S
Hex Head
Screws
Slot
Cabinet
Attaching
Screws
Figure 34
DRY861S
Cylinder Glide
Attaching
Screws
Seal must be
positioned under
flanged edge
Tape
Spring
Felt
Seal
Seal Strap
(Installed
with
cupped
surface
against
seal)