Display
Description
Cause/ Corrective Action
EC18
No Communication
Card reader initialized, communication
lost. Power down, power up and try again.
If error persists, replace control or card
reader.
EC19
No Card Reader Communication and No
Card Reader Initialization
Communication failure. Power down,
power up, check connections, harness and
try again. If error persists, replace control
or card reader.
EC36
Audit Card Removed Prematurely
Re-insert Audit Card and wait until ma-
chine prompts for card removal.
Right most decimal point Lit
Network Communication Error
Communication problem. Wait for 1.5 mi-
nutes for error to clear. If error doesn’t
clear, power-down and power-up the ma-
chine. Check all network connections. If
error persists, replace control or network
board.
ALArn
ALm
Break-in Alarm Error
Service the service door or coin vault
switches.
oFF
Break-in Alarm Shutdown Error
Service the service door or coin vault
switches.
Err
Coin Error
Invalid coin pulse or inoperative coin sen-
sor. Check coin drop area and remove ob-
structions. If error persists, tampering may
have occurred. Evaluate security proce-
dures.
E SH
Shorted Thermistor Error
Dead short in thermistor circuit. Check
wiring harness and remove any lint build-
up around thermistor. If problem persists,
replace thermistor or output board.
E oP
Open Thermistor Error
Physical open in thermistor circuit. Check
wiring harness and remove any lint build-
up around thermistor. If problem persists,
replace thermistor or output board.
E id
Board ID
Incorrect replacement control. Replace
user control or output board with correct
part.
Table 5
continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -