3. When the control enters the Factory Test Cycle, it will first
display
dr
for product type (dryer).
4. When the control enters the Factory Test Cycle, it will first
display
td
for product type (tumble dryer).
5. The control will advance through the sequence of test steps
whenever the START (enter) keypad is pressed, with the ex-
ception of the Keypad Test. Refer to
for all
tests in the Factory Test Cycle.
To Exit Factory Test Cycle
The test will be exited when the time reaches
00
on the control in
Step #10. Otherwise, the control must be powered down to end
the test.
Factory Test Cycle Quick Reference Table
Display
Test Mode
Comments
dr
Machine Type
dr
is the machine type (dryer)
Sxx
SXXX
Software Version
xxXXX
is the software version number.
obxx
Output Board Version Number
xx
is the output board version number.
Ax
Control Type
x
is the feature level of the control.
xx
DipSwitch Configuration
xx
is the machine type.
00
is 120V and
01
is 240V.
PAd
or
PAxx
Keypad Test
When a key is pressed, the control will
display the number assigned to the keypad
(1 - HIGH TEMP, 2 - LOW TEMP, 3 - NO
HEAT, 4 - MED TEMP, 5 - DELICATES,
6 - START)(4 - HIGH TEMP, 5 - LOW
TEMP, 7 - MED TEMP, 8 - DELICATES,
9 - START). As each keypad is pressed, its
corresponding LED will be lit and remain
on for the duration of the test. When all
keypads have been pressed, the control
will advance to Show Entire Display Mode
test cycle.
All LEDs and display segments will light
Show Entire Display Mode
This mode will light all display elements.
CXCX
Coin Drop Test
x
is the number of coins entered. If dual
coin drops are installed, coin drop #1 will
be shown on the left of the display and
coin drop #2 will be shown on the right
of the display. If a single coin drop is
used, only one coin count will increment.
U oP
or
U CL
v oP
or
v CL
Coin Vault Switch Test
oP
signifies the coin vault switch is open
or
CL
signifies the coin vault switch is
closed.
S oP
or
U CL
Service Door Switch Test
oP
signifies the service door switch is
open or
CL
signifies the service door
switch is closed.
Table 4
continues...
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
36
Part No. D515810ENR3
Summary of Contents for PD3JGBGS403UG01