800793
59
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: When installing new cap screw, apply a
thread locking compound to screw threads and
torque new cap screw to 240 minimum to 260
maximum inch pounds (27.5 to 29.7 Nm).
h. After installing belt, adjust belt tension as
follows:
(1) Working through the access door opening,
place a locking pliers on the metal rod and
loosen the two adjusting bolts. Refer to
Figure 23. Repeat procedure to loosen the
two pivot bolts. Refer to Figure 23.
(2) Pull down on motor to increase belt tension.
Use a Burroughs belt gauge to obtain
proper tension. Proper belt tension is
obtained when belt can be deflected
approximately 1/4 inch (6.35 mm) from
normal position when moderate pressure 50
to 60 pounds (22.68 to 27.22 Kg) is applied
to a point midway between pulleys. Refer
to Figure 23.
(3) After proper belt tension has been obtained,
tighten belt adjusting bolts firmly, then
tighten pivot bolts. Refer to Figure 23.
Figure 23
FLW1119S
BELT
INNER
BASKET
PULLEY
1/4 INCH
MOTOR
PULLEY
PIVOT
BOLT
ADJUSTING
BOLT
METAL
ROD
GROUND
WIRE
ADJUSTING
BOLT
PIVOT
BOLT
MOTOR
MOUNTING
BRACKET