505692
27
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
27. INNER AND OUTER DOOR PANELS AND
DOOR PULL
a. Remove four screws holding door assembly to
b. Remove remaining screws around the door
perimeter and separate panels. See Figure 9.
c. Remove wedge (located behind door pull) by
carefully prying up on center of wedge. See
Figure 8.
d. Remove door pull. See Figure 8.
Figure 8
D359PE3A
DOOR SEAL
DOOR
STRIKE
DOOR HINGE
DOOR STRIKE
BRACKET
SCREWS
INNER DOOR PANEL
AND SEAL ASSEMBLY
SCREW
DOOR
PULL
WEDGE
SCREW
FRONT
PANEL
OUTER DOOR
PANEL
COMMERCIAL DOOR
NOT SHOWN