Section 4 Grounding
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
16. GROUND WIRES FROM POWER CORD TO REAR BULKHEAD AND FROM REAR BULKHEAD
TO CONTROL HOUSING. CHECK WALL RECEPTACLE POLARITY (GAS MODELS ONLY).
See Figure 2.
NOTE: A qualified electrician should check the polarity of the wall receptacle. If a voltage reading is
measured other than that illustrated, the qualified electrician should correct the problem.
Figure 2
GROUND
WIRES
NEUTRAL
SIDE
115±12
V.A.C.
115±12
V.A.C.
0
V.A.C.
D236SE3B
GROUND
L1
NEUTRAL