AllerAir AirMedic+ Series Operation And Maintenance Manual Download Page 5

Visit our indoor air quality library: http://www.allerair.com/air-quality-library/index.html

5

4000/5000/6000 Series

ALLERAIR’S AIR PURIFICATION SYSTEM

LASER TESTED TRUE HEPA

HEPA (High Efficiency Particulate Arrestance) filters were developed for the Atomic Energy 
Commission to remove radio active dust from their laboratories. They are now the primary filtration 
systems for electonic clean room assembly, hospital surgeries, bio engineering, pharmaceutical 
laboratories and any other space where clean air is critical.

HEPA will trap microscopic dust which may contribute to allergies, asthma, respiratory problems, 
chemical sensitivities and sick building syndrome. It will trap 99.97% of all particles down to 0.3 
microns (including bacteria, dust mite antigens, respiratory particles, fungal and other 
microbiologicals). For these reasons HEPA filtration is recommended by more allergists, medical 
professionals and clean air consultants than any other filter system available. 

CARBON FILTER (ACTIVATED AND GRANULATED)

We use only activated granular carbon mixed with zeolite and specially impregnated carbons. We 
stay away from dust carbon that has been impregnated onto a poly or foam material. This type of 
carbon filter may need to be changed weekly to be fully effective. AllerAir's carbon filter can last up 
to 2 or 3 years and more, depending on the level of toxins in the area. 

The activated carbon we use can adsorb up to 60% of its own weight in toxic gases, fumes and 
chemicals. These toxic substances may make us ill, and are found in every home, office and industry.

OTHER FILTERING SYSTEMS AVAILABLE

Ozone generators, negative ion machines and electrostatically charged units all generate ozone 
which is a toxic substance. Any unit which provides ozone cannot be recommended by Health and 
Welfare or by the Lung Association.

AllerAir's units on the other hand, do not produce any ozone whatsoever. AllerAir air purifiers scrub 
impurities and toxins out of the air.

ENERGY COSTS

We use a high efficiency motor which costs pennies a day to operate in contrast to many other 
manufacturers who use the lowest priced motor available.  One of the reasons we can offer a ten 
year warranty is because of the sophisticated motor we use.  We have spared no effort to give you 
the most benefits for the least cost.

When using your air purifier in a freshly painted room, you should first remove the HEPA filter from 
the unit to avoid contaminating the HEPA filter. Turn unit off and unplug unit. Remove bottom 
screws. Remove bottom and gasket - remove the center HEPA filter - replace gasket and bottom, 
making sure that the arrow is aligned with the seam of the unit - plug into grounded receptacle then 
turn on. Replace carbon filter before reinstalling HEPA filter.

PLANNING ON PAINTING YOUR HOME? READ THIS FIRST:

IMPORTANT NOTICE!

Summary of Contents for AirMedic+ Series

Page 1: ...ak efficiency Model No ___________________ Serial No ___________________ Operation and Maintenance Manual AirMedic Series Note As original packaging is required for warranty returns new AllerAir owners are advised to keep boxes and shipping materials Operation Most AirMedic units are shipped fully assembled and ready for use with the exception of the D model which ship with their large carbon filt...

Page 2: ...ENANCE The HEPA Filter Change the HEPA filter every 3 5 years or after a noticeable decrease in air quality The Pre Filter Change or vacuum the pre filter every 2 4 months depending on the dust level in the area of use The Carbon Filter Change the carbon filter after 2 years or after a noticeable decrease in air quality REPLACEMENT PARTS Models Pre filters Notes N6FMPW001 White pre filter Packs of...

Page 3: ... wheels STEP 1 Turn power off and unplug from receptacle Lay unit upside down STEP 2 With a 2 Philips screwdriver remove the four screws from the bottom of the unit STEP 4 Reach inside the unit and remove only 1 of the 2 gasket pads STEP 5 Insert the HEPA filter STEP 6 Gently insert the carbon filter into the unit STEP 8 Place lid back to its proper position by aligning the arrow with the rear sea...

Page 4: ...hite donut shaped gaskets from the inside of the purifier body STEP 5 Insert the carbon filter STEP 6 Replace the gasket that had been removed in STEP 4 STEP 3 Gently grasp wheels Remove the base by pulling gently on the wheels STEP 1 Turn power off and unplug from receptacle Lay unit upside down STEP 2 With a 2 Philips screwdriver remove the four screws from the bottom of the unit DO NOT ALLOW AN...

Page 5: ...up to 2 or 3 years and more depending on the level of toxins in the area The activated carbon we use can adsorb up to 60 of its own weight in toxic gases fumes and chemicals These toxic substances may make us ill and are found in every home office and industry OTHER FILTERING SYSTEMS AVAILABLE Ozone generators negative ion machines and electrostatically charged units all generate ozone which is a ...

Page 6: ...AllerAir 1 888 852 8247 info allerair com 6 NOTES Operating and Maintenance Manual ...

Page 7: ...Visit our indoor air quality library http www allerair com air quality library index html 7 4000 5000 6000 Series NOTES ...

Page 8: ...quired for warranty repairs Please contact AllerAir at 1 888 852 8247 for more information THE ALLERAIR ADVANTAGE Our units offer complete air filtration removing airborne chemicals gases odors and particles Our deep bed activated carbon filters last longer than the average thin filter which is generally carbon sprayed onto a synthetic material Our units do not use dangerous ozone technology Our u...