2-10
SECTION 2
OPERATIONS
056335; 01/12
2.3, continued
Operating Instructions
2.3.5 Cold Weather Startup Procedures
When ambient temperatures are below 60°F (16°C) cold weather startup procedures
must be followed before bringing machine into maximum engine RPM and rotor speed.
If the procedure is not followed, damage could occur which will void the warranty.
See below for startup procedure.
A
When ambient temperatures are below 60°F (16°C) run engine at 1/4” throttle. There is an
arrow (A) located on a decal showing where the throttle lever’s front edge should be located.
Engage the rotors by pressing on the right foot pedal for approximately 5 to 7 minutes to allow
the hydraulic system and engine system time to adequately warm up before operation.
Summary of Contents for HDX750
Page 1: ...HDX750 056335 01 12 Hydra Drive Extreme HDX Series Riding Trowel OPERATIONS PARTS MANUAL ...
Page 17: ...1 1 056335 01 12 SECTION 1 SAFETY Section 1 SAFETY ...
Page 29: ...2 1 056335 01 12 SECTION 2 OPERATIONS Section 2 OPERATIONS ...
Page 39: ...3 1 056335 01 12 SECTION 3 SERVICE Section 3 SERVICE ...
Page 49: ...4 1 056335 01 12 SECTION 4 PARTS Section 4 PARTS ...
Page 72: ...4 24 SECTION 4 PARTS 056335 01 12 4 8 Illustration Hydraulic Schematic ...
Page 73: ...4 25 056335 01 12 SECTION 4 PARTS 4 8 Illustration Hydraulic Schematic ...
Page 74: ...4 26 SECTION 4 PARTS 056335 01 12 4 9 Illustration Electrical Harness Schematic ...
Page 75: ...4 27 056335 01 12 SECTION 4 PARTS 4 9 Illustration Electrical Harness Schematic ...
Page 80: ...4 32 SECTION 4 PARTS 056335 01 12 ...
Page 81: ...056335 01 12 INTENTIONALLY BLANK ...
Page 82: ...056335 01 12 YOUR TOTAL SOURCE FOR CONCRETE EQUIPMENT ...