Sensing/Misalignment Curve
Typical Wiring Diagram
Description
Plastic
8-Pin Micro (M12)
Grey
Safety A
Red
Safety A+
Pink
Safety B
8-Pin Cordset
Yellow
Safety B+
889D-F8AB-*
White
Aux A
or cable version
Brown
24V DC+
Blue
Gnd / 0V
Green
N/A
* Replace symbol with 2 (2m), 5 (5m) or 10 (10m) for standard cable lengths.
Diagnostic
Unit Indicators (per IEC 60073)
State
Status
Troubleshooting
Off
Not Powered
NA
Status/Diag
Red
Not Safe, OSSD not active
NA
LED
Green
Safe, OSSD active
NA
Green flash
Power up test or OSSD
Check 24V DC or OSSD inputs
inputs not valid
(yellow and red wire)
Red Flash
1 Hz Flash Recoverable Fault
Recoverable fault —check OSSD
4 Hz Flash Non-recoverable Fault
outputs are not shorted to GND,
24V DC or each other. Cycle power.
Amber
1 Hz Flash margin indicator
Sensor is reaching max. sensing
Flash
safe, OSSD active
distance; re-align sensor
with actuator
PN-114371 dir 10000182958 ver 00
SensaGuard
TM
Installation Instructions
5
2-24V DC+
1-Aux A
7-0V
6-Safety B
3-N/A
8-Safety A+
4-Safety B+
5-Safety A
Note:
Refer to Technical Specifications for Certification information and ratings.
0
5
10
15
20
25
30
35
Assured Make: 15mm
Assured OFF : 27mm
SIDE
LOBES
SIDE
LOBES
ASSURED
SENSING
DISTANCE
Sensing Distance (mm)
Note:
There must be a minimum spacing of 9mm (0.35”) if the actuator and sensor face approaches
laterally.This will prevent false triggering due to the side lobes areas.
Allen-Bradley 440N-Z21SS2AN9