6
Rockwell Automation Publication 1732IL-IN001B-EN-P - April 2019
ArmorBlock 16-Channel IO-Link Hubs
Connect the I/O and IO-Link Cables to the Hub
ArmorBlock 16-Channel IO-Link hubs have one 5-pin M12 style IO-Link interface connector and eight 5-pin M12 style
I/O connectors for sensors. The 1732IL-16CFGM12M12L IO-Link hub also has a 5-pin M12 style power connector. All connectors need to be
covered or cable terminated to maintain the IP rating. Connect the cordsets that you selected for your hub to the appropriate connectors.
IO-Link Interface
M12 Style, 5-pin, A-Coded IO-Link Male Connector — 1732IL-IB16M12 and 1732IL-16CFGM12M12L
M12 Style, 5-pin, A-Coded IO-Link Male Connector — 1732IL-10X6M12
I/O Ports
M12 Style, 5-pin, A-Coded I/O Female Connector — 1732IL-IB16M12, 1732IL-10X6M12 Input
M12 Style, 5-pin, A-Coded I/O Female Connector — 1732IL-16CFGM12M12L
3
4
1
2
5
Pin
Value
Function
1
+24V DC (L+)
Supply voltage from IO-Link master
2
NC
Not connected
3
GND (L-)
Reference potential to L+
4
C/Q (IO-Link)
IO-Link data channel
5
NC
Not connected
View into Connector
3
4
1
2
5
Pin
Value
Function
1
+24V DC (L+)
Supply voltage from IO-Link master
2
+24V DC (2L+)
Additional supply voltage
3
GND (L-)
Reference potential to L+
4
C/Q (IO-Link)
IO-Link data channel
5
GND (2L-)
Reference potential for additional supply voltage
View into Connector
4
3
2
1
5
Pin
Value
Function
1
Us
Sensor source voltage
2
In B
Digital input (Odd channels)
3
GND
Reference potential
4
In A
Digital input (Even channels)
5
FE
Functional earth
View into Connector
3
4
1
2
5
Pin
Value
Function
1
+24V DC
Sensor source voltage
2
In/Out B
Digital I/O (Odd channels)
3
GND 0V
Reference potential
4
In/Out A
Digital I/O (Even channels)
5
FE
Functional earth