Rockwell Automation Publication 1732IL-IN001B-EN-P - April 2019

3

ArmorBlock 16-Channel IO-Link Hubs

Environment and Enclosure

Prevent Electrostatic Discharge

Electrical Safety Considerations

ATTENTION: 

This equipment is intended for use in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) 

without derating.

This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such 
environments.

This equipment is supplied as enclosed equipment. It should not require additional system enclosure when used in locations consistent with the equipment 
Enclosure Type Ratings. Subsequent sections of this publication may contain more information regarding specific enclosure type ratings, beyond what this 
product provides, that are required to comply with certain product safety certifications.

In addition to this publication, see the following:

• Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

, for more installation requirements.

• NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures.

WARNING: 

Special Conditions for Safe Use:

• Make sure that all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP enclosure type requirements.
• Do not connect or disconnect under voltage!
• Read this document and the documents listed in the Additional Resources section about installation, configuration, and operation of this equipment before 

you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to 
requirements of all applicable codes, laws, and standards. 

• Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in 

accordance with applicable code of practice.

• In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle the 

module.

ATTENTION: 

This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when 

you handle this equipment:

• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

ATTENTION: 

Power to this equipment and all connected I/O must be supplied from a source compliant with the following:

• SELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1) 
• PELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1) 

IMPORTANT

Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for the purposes of example. Since there are 
many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability for actual use 
based upon the examples shown in this publication.

At the end of its life, this equipment should be collected separately from any unsorted municipal waste.

Summary of Contents for Rockwell Automation ArmorBlock 1732IL-10X6M12

Page 1: ...red with the Studio 5000 Logix Designer application For more information on how to use IO Link hub including the compatible Logix 5000 controllers and Studio 5000 Logix Designer application versions s...

Page 2: ...ti nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio...

Page 3: ...efore you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes...

Page 4: ...Components Needed to Install an IO Link Hub Component Description Tools You need the following tools Screwdriver 1 Functional earth is provided for the grounding of field devices and is internally co...

Page 5: ...ccommodate M4 x 25 30 mm screws with toothed lock washer for example a DIN 125 screw and self locking nuts The torque specification is 1 0 Nm 8 85 lb in IO LinkHubDimensions See the mounting dimension...

Page 6: ...6M12 1732IL 10X6M12 Input M12 Style 5 pin A Coded I O Female Connector 1732IL 16CFGM12M12L 3 4 1 2 5 Pin Value Function 1 24V DC L Supply voltage from IO Link master 2 NC Not connected 3 GND L Referen...

Page 7: ...to PELV protective extra low voltage or SELV safety extra low voltage Power supplies according to EN 61558 2 6 transformers or EN 60950 1 switching power supply units fulfill these requirements 3 4 1...

Page 8: ...rges 8 kV air discharges Radiated RF Immunity IEC 61000 4 3 10V m with1 kHz sine wave 80 AM from 80 2000 MHz 10V m with200 Hz 50 Pulse 100 AMat 900 MHz 10V m with200 Hz 50 Pulse 100 AMat 1890 MHz 10V...

Page 9: ...on com global support get support now page Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer http www rockwellautoma...

Page 10: ...10 Rockwell Automation Publication 1732IL IN001B EN P April 2019 ArmorBlock 16 Channel IO Link Hubs Notes...

Page 11: ...Rockwell Automation Publication 1732IL IN001B EN P April 2019 11 ArmorBlock 16 Channel IO Link Hubs Notes...

Page 12: ...omasyon Ticaret A Kar Plaza Merkezi E Blok Kat 6 34752 erenk y stanbul Tel 90 216 5698400 Rockwell Automation maintains current product environmental information on its website at http www rockwellaut...

Reviews: