Rockwell Automation Publication 520-UM002B-EN-E - December 2017
51
Chapter
3
Configuring the PowerFlex 527 Drive with
Integrated Motion
This chapter procedures on how to set up Integrated Motion on the EtherNet/IP
network control by using a PowerFlex® 527 Drive.
Configure the Drive
You can include the drive in your Studio 5000 Logix Designer® application by
adding it to a configured EtherNet/IP module or controller and adding it under
the I/O configuration tree. After setting the network configuration, you can view
the drive status information in Studio 5000® software and use it in your
Studio 5000 Logix Designer application.
Set the Network Configuration
You can set the network configuration by using the LCD display and drive
keypad.
1.
When the LCD display is showing the Device/Axis state, use the keypad
to navigate to SETTINGS -> NETWORK. Then choose either STATIC
IP or DHCP.
The default setting is STATIC IP.
2.
If you chose STATIC IP, then you must configure the following settings:
•
IP address
•
Gateway
•
Subnet mask
For information on...
See page...
Configure the Logix Designer Application Project
Configure the PowerFlex 527 Drive
Apply Power to the PowerFlex 527 Drive
Test and Tune the Axes – Velocity and Position Control Modes
TIP
Before you begin, make sure you know the catalog number for each drive
component, the Logix module and /or controller used in your motion control
application.
Summary of Contents for PowerFlex 527
Page 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Page 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Page 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Page 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Page 175: ......