Allen-Bradley PowerFlex 4 Quick Start Manual Download Page 10

English-10

A070
A071
A072
A073

[Preset Freq 0]

(1)

[Preset Freq 1]
[Preset Freq 2]
[Preset Freq 3]

0.0/240.0 Hz

0.1 Hz

0.0 Hz
5.0 Hz
10.0 Hz
20.0 Hz

(1) 

To activate [Preset Freq 0] set P038 [Speed Reference] to option 4.

A078 [Jog Frequency]

0.0/[Maximum Freq]

0.1 Hz

10.0 Hz

A079 [Jog Accel/Decel]

0.1/600.0 Secs

0.1 Secs

10.0 Secs

A080 [DC Brake Time]

0.0/90.0 Secs

0.1 Secs

0.0 Secs

A081 [DC Brake Level]

0.0/(Drive Amps 

×

 1.8) 0.1 Amps

Amps 

×

 0.05

A082  [DB Resistor Sel]

0/99

0 = Disabled
1 = 5% Duty Cycle

2 = 100% Duty Cycle
3-99 = % of Duty Cycle

0

A083 [S Curve %]

0/100%

1%

0% (Disabled)

A084 [Start Boost]

1/14

Settings in % of base voltage.

8
7 (5 HP Drives)

Variable Torque

Constant Torque

1 = “30.0”

5 = “0.0 no IR Comp” 10 = “10.0”

2 = “35.0”

6 = “0.0”

11 = “12.5”

3 = “40.0”

7 = “2.5”

12 = “15.0”

4 = “45.0”

8 = “5.0”

13 = “17.5”

9 = “7.5”

14 = “20.0”

A088 [Maximum Voltage]

20/Rated Volts

1 VAC

Rated Volts

A089 [Current Limit]

0.1/(Drive Amps 

×

 1.8) 0.1 Amps

Amps 

×

 1.5

A090 [Motor OL Select]

0/2

0 = “No Derate”

1 = “Minimum Derate”
2 = “Maximum Derate”

0

A091 [PWM Frequency]

2.0/16.0 kHz

0.1 kHz

4.0 kHz

A092 [Auto Rstrt Tries]

0/9

1

0

A093 [Auto Rstrt Delay]

0.0/120.0 Secs

0.1 Secs

1.0 Secs

A094 [Start At PowerUp]

0/1

0 = “Disabled”

1 = “Enabled”

0

A095 [Reverse Disable]

0/1

0 = “Reverse Enabled”

1 = “Reverse Disabled”

0

A096 [Flying Start En]

0/1

0 = “Disabled”

1 = “Enabled”

0

A097 [Compensation]

0/3

0 = “Disabled”
1 = “Electrical”

2 = “Mechanical”
3 = “Both”

1

A098 [SW Current Trip]

0.0/(Drive Amps 

× 

2)

0.1 Amps

0.0 (Disabled)

A099 [Process Factor]

0.1/999.9

0.1

30.0

A100 [Fault Clear]

0/2

0 = “Ready”

1 = “Reset Active Fault”
2 = “Clear Fault Queue”

0

A101 [Program Lock]

0/1

0 = “Unlocked”

1 = “Locked”

0

A102 [Testpoint Sel]

0/FFFF

1 Hex

400

A103 [Comm Data Rate]

(3)

0/5

0 = “1200”
1 = “2400”
2 = “4800”

3 = “9600”
4 = “19.2K”
5 = “38.4K”

3

A104 [Comm Node Addr]

(3)

1/247

1

100

A105 [Comm Loss Action]

0/3

0 = “Fault”
1 = “Coast to Stop”

2 = “Stop”
3 = “Continue Last Speed”

0

A106 [Comm Loss Time]

0.1/60.0

0.1

5.0

A107 [Comm Format]

(3)

0/2

0 = “RTU 8-N-1”

1 = “RTU 8-E-1”
2 = “RTU 8-O-1”

0

A110 [0-10V Analog Input 

Low]

0.0/100.0%

0.1%

0.0

A111 [0-10V Analog Input 

High]

0.0/100.0%

0.1%

100.0

A112 [4-20mA Analog Input 

Low]

0.0/100.0%

0.1%

0.0

A113 [4-20mA Analog Input 

High]

0.0/100.0%

0.1%

100.0

A114 [Slip Compensation]

0.0/10.0 Hz

0.1 Hz

2.0 Hz

(3)

 Power to drive must be cycled before any changes will affect drive operation.

No.

Parameter

Min/Max

Display/Options

Default

Input State of Digital In 1

(I/O Terminal 05)

Input State of Digital In 2

(I/O Terminal 06)

Frequency Source

Accel / Decel Parameter Used 

(2)

0

0

[Preset Freq 0]

[Accel Time 1] / [Decel Time 1]

1

0

[Preset Freq 1]

[Accel Time 1] / [Decel Time 1]

0

1

[Preset Freq 2]

[Accel Time 2] / [Decel Time 2]

1

1

[Preset Freq 3]

[Accel Time 2] / [Decel Time 2]

(2) 

When a Digital Input is set to “Accel 2 & Decel 2”, and the input is active, that input overrides the settings in this table.

See the PowerFlex 4 User Manual on CD for more information on parameters.

All manuals and user guides at all-guides.com

Summary of Contents for PowerFlex 4

Page 1: ...2 Auto Rstrt Tries A094 Start At PowerUp is used in an inappropriate application Do not use this function without considering applicable local national and international codes standards regulations or...

Page 2: ...56 1 96 Nm 14 17 lb in AmbientTemperature Enclosure Rating Minimum Mounting Clearances Minimum Maximum 10 C 14 F 40 C 104 F IP 20 Open Type Use Mounting Option A IP 30 NEMA 1 UL Type 1 1 1 Rating requ...

Page 3: ...Efficiency 97 5 Typical Digital Control Inputs Input Current 6mA Analog Control Inputs SRC Source Mode 18 24V ON 0 6V OFF SNK Sink Mode 0 6V ON 18 24V OFF 4 20mA Analog 250 ohm input impedance 0 10V D...

Page 4: ...endations Input Power Condition Corrective Action Low Line Impedance less than 1 line reactance Install Line Reactor 2 or Isolation Transformer Greater than 120 kVA supply transformer Line has power f...

Page 5: ...0 ohm P038 16 RS485 DSI Shield Terminal should be connected to safety ground PE when using the RS485 DSI communications port 3 Only one analog frequency source may be connected at a time If more than...

Page 6: ...ny Program Group parameters Start Stop Direction and Speed Control Factory default parameter values allow the drive to be controlled from the integral keypad No programming is required to start stop c...

Page 7: ...gramming menu Cancel a change to a parameter value and exit Program Mode Select Advance one step in programming menu Select a digit when viewing parameter value Up Arrow Down Arrow Scroll through grou...

Page 8: ...parameters that are in the group 7 Press Enter or Sel to view the value of a parameter If you do not want to edit the value press Esc to return to the parameter number 8 Press Enter or Sel to enter p...

Page 9: ...control When in three wire control I O Terminal 01 is controlled by P037 Stop Mode 1 Stop input also clears active fault P038 Speed Reference 0 5 0 Drive Potentiometer 1 Internal Freq 2 0 10V Input R...

Page 10: ...Mechanical 3 Both 1 A098 SW Current Trip 0 0 Drive Amps 2 0 1 Amps 0 0 Disabled A099 Process Factor 0 1 999 9 0 1 30 0 A100 Fault Clear 0 2 0 Ready 1 Reset Active Fault 2 Clear Fault Queue 0 A101 Pro...

Page 11: ...urrent Limit F7 Motor Overload 1 An excessive motor load exists Reduce load so drive output current does not exceed the current set by parameter P033 Motor OL Current F8 Heatsink OvrTmp 1 Check for bl...

Page 12: ...9 87 4 3 44 168 6 61 2 2 4 9 1 Overall height of drive with IP 30 NEMA 1 UL Type 1 option kit installed 2 Overall height of standard IP 20 Open Type drive Frame 120V AC 1 Phase 240V AC 1 Phase 240V AC...