Wiring Diagrams

Specifications

General specifications - These specifications are 

shared by all components

 of the 1734 POINT I/O system.

1734-TB, -TBS, -TB3 and -TB3S Specifications

 

Out 

0

Out 

1

Out 

1

Out 

0

C

C

V

V

Load

Load

42014

V = 12/24V dc, C = Common
Field power is supplied from power bus

1734-OB2E

Out 

0

Out 

1

Out 

3

Out 

2

C

C

C

C

Load

Load

42015

Load

Load

V = 12/24V dc, C = Common
Field power is supplied from power bus

1734-OB4E

In 

0

In 

1

C

C

V

V

In 0

In 1

V = 12/24V dc, C = Common Chass GND = Chassis Ground
This supply will be connected to the internal power bus.

42017

1734-IE2C

42018

Out 

0

Out 

1

C

C

V

V

Out 0

Out 1

V = 12/24V dc, C = Common
Chass GND = Chassis Ground
This supply will be connected to
the internal power bus.

1734-OE2C

Load

Out 

0A

C

V

V

C

Load

V = 12/24V dc, C = Common
This supply will be connected to 
the internal power bus.

Out 

1A

Out 

1B

Out 

0B

42019

1734-OW2

0

4

2

6

1

5

3

7

0

4

2

6

1

5

3

7

0

4

2

6

1

5

3

7

0

4

2

6

1

5

3

7

0

4

2

6

1

5

3

7

Chass 
Gnd

Chass 
Gnd

Chass 
Gnd

Chass 
Gnd

A

Anot

B

Z

FE

FE

Znot

Bnot

A, B, Z, Anot, Bnot,
and Znot = inputs
FE = Functional Earth

41975

0

4

2

6

1

5

3

7

1734-IJ, & 1734-IK

A

Anot

B

Z

Out 0 Out 1

Znot

Bnot

A, B, Z, Anot, Bnot, and Znot = inputs
FE = Functional Earth
-Vaux = Auxiliary Supply
+Vaux = Auxiliary Supply

42444

FE

FE

RET 0

-Vaux -Vaux

RET 1

+Vaux +Vaux

1734-VHSC24, & 
1734-VHSC5

0

4

2

6

1

5

3

7

0

4

2

6

1

5

3

7

Specification:

Value:

Specification:

Value:

Environ. Conditions

Operating Temp.
Storage Temp.
Relative Humidity

Shock

Operating

Non-operating
Vibration

-20 to 55

o

C (-4 to 131

o

F)

-40 to 85

o

C (-40 to 185

o

F)

5 to 95% noncondensing

30g peak acceleration, 11(±1)ms pulse width
50g peak acceleration, 11(±1)ms pulse width

Tested 5g @ 10-500Hz per IEC 68-2-6

Conductors

Wire Size

Category

14 AWG (2.5mm

2

) - 22 AWG (0.25mm

2

)

solid or stranded max

(18 AWG max if connecting 2 wires to same terminal)

3/64 inch (1.2mm) insulation max

2

1

Terminal Base Screw 
Torque

7 inch-pounds max

Agency Certification 
(When Product or 
Packaging is Marked)

CE marked for all applicable directives
C-Tick marked for all applicable acts
CUL listed – Class I, Division 2

Groups A, B, C and D certified

CUL recognized
DeviceNet conformance tested

1

Use this conductor category information for planning conductor routing as described in the system level installation manual.

Specification:

1734-TB, -TBS, -TB3, -TB3S

Specification:

1734-TB, -TBS, -TB3, -TB3S

Field Power Bus

Voltage

240V ac (1734-TB, -TBS)
28.8V dc, 120/240V ac (1734-TB3, -TB3S)

Dimensions 
(HxWxL)

65mm x 12mm x 133.4mm 
(2.560in x 0.472in x 5.250in) (1734-TB, -TBS)
65mm x 12mm x 160mm 
(2.560in x 0.472in x 6.25in) (1734-TB3, -TB3S)

Current

10A max

Mass

2.94 oz/83.35 grams (1734-TB)
2.57 oz/73.86 grams (1734-TBS)
3.44 oz/97.5 grams (1734-TB3)
3.07 oz/87 grams (1734-TB3S)

Allen-Bradley Motors

Summary of Contents for POINT I/O 1734-ADN

Page 1: ...supplied with your terminal base To remove pull up on the RTB removal handle This allows the base to be removed and replaced as necessary without removing any of the wiring To reinsert the removable...

Page 2: ...round This supply will be connected to the internal power bus 0 4 2 6 1 5 3 7 V ac NC L2 N L1 NC L2 N L1 Daisy chain power out to modules 120 240V ac Power L2 N Neutral L1 120 240V ac This supply will...

Page 3: ...Vaux Auxiliary Supply 42444 FE FE RET 0 Vaux Vaux RET 1 Vaux Vaux 1734 VHSC24 1734 VHSC5 0 4 2 6 1 5 3 7 0 4 2 6 1 5 3 7 Specification Value Specification Value Environ Conditions Operating Temp Stor...

Page 4: ...hassis Ground 4 Common 5 Common 6 Supply 7 Supply Power Supply Specifications Power Supply Note In order to comply with CE Low Voltage Directives LVD you must use a Safety Extra Low Voltage SELV or a...

Page 5: ...500V rms V for 1s 1734 IM2 Dimensions Inches Millimeters 2 21H x 0 47W x 2 97L 56 0H x 12 0W x 75 5L External AC Power Supply Voltage 120V ac 60Hz nominal 1734 IA2 220V ac 60Hz nominal 1734 IM2 Extern...

Page 6: ...output on signal to output energization On off delay is time from a valid output off signal to output deenergization Specification Value Specification Value Module Location 1734 TB or TBS terminal ba...

Page 7: ...1 24V dc input compliant 2 Input OFF to ON and ON to OFF filter time is the time from a valid input signal to recognition by the module Specification Value Specification Value Module Location 1734 TB...

Page 8: ...ift w Temp 30ppm C Maximum Overload Fault protected to 28 8V dc Resist Load on mA Output 0 330 Indicators 4 green red indicators Mass 1 22 oz 34 59 grams 1 26 oz 25 72 grams Power Dissipation 0 5W max...

Page 9: ...1 0MHz counter and encoder X1 configurations 500kHz encoder X2 configuration no filter 250kHz encoder X4 configuration no filter Module Location 1734 TB TBS TB3 TB3S wiring base assembly Pointbus Curr...

Page 10: ...1 25V dc 1734 VHSC5 Input ON State Current 5mA Input ON State Voltage 12 5V dc 1734 VHSC24 2 6V dc 1734 VHSC5 Output Specifications 1734 VHSC24 VHSC4 Number of Outputs 1 isolated group of 2 capable of...

Page 11: ...2 Industrial Environment EN 50082 2 EMC Generic Immunity Standard Part 2 Industrial Environment This product is intended for use in an industrial environment Low Voltage Directive This product is tes...

Page 12: ...12 POINT I O Publication 1734 IN510B EN P August 2000 PN 957395 13 Supersedes Publication 1734 5 10 September 1999 2000 Rockwell International Corporation Printed in the U S A...

Reviews: