Allen-Bradley POINT I/O 1734-ADN Installation Instructions Manual Download Page 11

POINT I/O        

11

Publication 1734-IN510B-EN-P - August 2000

European Communities (EC) Directive Compliance

If this product has the CE mark it is approved for installation within 
the European Union and EEA regions. It has been designed and tested 
to meet the following directives.

EMC Directive

This product is tested to meet the Council Directive 89/336/EC Electro-
magnetic Compatibility (EMC) by applying the following standards, in 
whole or in part, documented in a technical construction file:

EN 50081-2 EMC — Generic Emission Standard, Part 2 — 
Industrial Environment

EN 50082-2 EMC — Generic Immunity Standard, Part 2 — 
Industrial Environment

This product is intended for use in an industrial environment.

Low Voltage Directive

This product is tested to meet Council Directive 73/23/EEC Low 
Voltage, by applying the safety requirements of EN 61131-2 
Programmable Controllers, Part 2 - Equipment Requirements and 
Tests. For specific information required by EN 61131-2, see the 
appropriate sections in this publication, as well as the Allen-Bradley 
publication Industrial Automation Wiring and Grounding Guidelines 
For Noise Immunity, publication 1770-4.1.

This equipment is classified as open equipment and must be mounted 
in an enclosure during operation to provide safety protection.

Allen-Bradley Motors

Summary of Contents for POINT I/O 1734-ADN

Page 1: ...supplied with your terminal base To remove pull up on the RTB removal handle This allows the base to be removed and replaced as necessary without removing any of the wiring To reinsert the removable...

Page 2: ...round This supply will be connected to the internal power bus 0 4 2 6 1 5 3 7 V ac NC L2 N L1 NC L2 N L1 Daisy chain power out to modules 120 240V ac Power L2 N Neutral L1 120 240V ac This supply will...

Page 3: ...Vaux Auxiliary Supply 42444 FE FE RET 0 Vaux Vaux RET 1 Vaux Vaux 1734 VHSC24 1734 VHSC5 0 4 2 6 1 5 3 7 0 4 2 6 1 5 3 7 Specification Value Specification Value Environ Conditions Operating Temp Stor...

Page 4: ...hassis Ground 4 Common 5 Common 6 Supply 7 Supply Power Supply Specifications Power Supply Note In order to comply with CE Low Voltage Directives LVD you must use a Safety Extra Low Voltage SELV or a...

Page 5: ...500V rms V for 1s 1734 IM2 Dimensions Inches Millimeters 2 21H x 0 47W x 2 97L 56 0H x 12 0W x 75 5L External AC Power Supply Voltage 120V ac 60Hz nominal 1734 IA2 220V ac 60Hz nominal 1734 IM2 Extern...

Page 6: ...output on signal to output energization On off delay is time from a valid output off signal to output deenergization Specification Value Specification Value Module Location 1734 TB or TBS terminal ba...

Page 7: ...1 24V dc input compliant 2 Input OFF to ON and ON to OFF filter time is the time from a valid input signal to recognition by the module Specification Value Specification Value Module Location 1734 TB...

Page 8: ...ift w Temp 30ppm C Maximum Overload Fault protected to 28 8V dc Resist Load on mA Output 0 330 Indicators 4 green red indicators Mass 1 22 oz 34 59 grams 1 26 oz 25 72 grams Power Dissipation 0 5W max...

Page 9: ...1 0MHz counter and encoder X1 configurations 500kHz encoder X2 configuration no filter 250kHz encoder X4 configuration no filter Module Location 1734 TB TBS TB3 TB3S wiring base assembly Pointbus Curr...

Page 10: ...1 25V dc 1734 VHSC5 Input ON State Current 5mA Input ON State Voltage 12 5V dc 1734 VHSC24 2 6V dc 1734 VHSC5 Output Specifications 1734 VHSC24 VHSC4 Number of Outputs 1 isolated group of 2 capable of...

Page 11: ...2 Industrial Environment EN 50082 2 EMC Generic Immunity Standard Part 2 Industrial Environment This product is intended for use in an industrial environment Low Voltage Directive This product is tes...

Page 12: ...12 POINT I O Publication 1734 IN510B EN P August 2000 PN 957395 13 Supersedes Publication 1734 5 10 September 1999 2000 Rockwell International Corporation Printed in the U S A...