Frame Size 83, 10 mm Roller Screw Load Correction
K
MPAI-x3xxxSM3xx
= 0.44 (F
Xpeak
/F
Xn
)-0.15
Frame Size 110, 5 mm Roller Screw Load Correction
K
MPAI-x4xxxSM3xx
= 0.26 (F
Xpeak
/F
Xn
)-0.15
Frame Size 110, 10 mm Roller Screw Load Correction
K
MPAI-x4xxxSM3xx
= 0.40 (F
Xpeak
/F
Xn
)-0.15
3.
Calculate the lubrication interval (
t
l
) in hours.
t
1
= t
bl
x K, h
Use the basic lubrication interval (t
bl
) and the load correction factor (K) from
step 1
and
step 2
.
4.
When the calculated lubrication interval elapses, refill the lubricant reservoir through
the grease fitting.
IMPORTANT
The maximum lubricant fill capacity for a roller screw drive is the following:
•
3.0 g of factory recommended lubricant for frame size 83
•
5.0 g of factory recommended lubricant for frame size 110