Allen-Bradley Kinetix 5000 Installation Instructions Manual Download Page 4

4

     Kinetix 5000 AC Line Filters

Rockwell Automation Publication 2198-IN003B-EN-P - March 2015

AC Line Filter Wiring Examples

L1

L2

L3

L1

L2

L3

PE

L1’

L2’

L3’

PE

240/480V

L1

L2

L3

L1

L2

L3

PE

L1’

L2’

L3’

PE

240V

L1

L2

L3

L1

L2

L3

PE

L1’

L2’

L3’

PE

480V

L1

L2

L3

L1

L2

L3

PE

L1’

L2’

L3’

PE

480V

L1

L2

L3

L1

L2

L3

Bonded Cabinet 
Ground Bar

2198-DB08-F

AC Line Filter

Line

Load

Bonded Cabinet 
Ground Bar

2198-DB

xx

-F

AC Line Filter

Kinetix 5500 drive input 
power (IPD) connections for 
three-phase operation.

Line

Load

Kinetix 5500 drive input 
power (IPD) connections 
for single-phase operation.

Bonded Cabinet 
Ground Bar

2198-DB

xx

-F

AC Line Filter

Circuit 

Protection

Kinetix 5700 drive input 
power (IPD) connections for 
three-phase operation.

Line

Load

2198-P

xxx

 DC-bus Power Supply

2198-H

xxx

-ERS

x

 Servo Drives

2198-H003-ERS

x

, 2198-H008-ERS

x

2198-H015-ERS

x

 Servo Drives

Mains

Contactor

Circuit 

Protection

Circuit 

Protection

Kinetix 5700 drive input 
power (IPD) connections for 
three-phase operation.

Bonded Cabinet 
Ground Bar

Circuit 

Protection

Mains

AC Input

Kinetix 5700 drive input 
power (IPD) connections for 
three-phase operation.

Line

Load

Mains

Contactor

2198-P208 DC-bus 

Power Supply

Kinetix 5700 drive input 
power (IPD) connections for 
three-phase operation.

2198-DB290-F

AC Line Filter

Mains

AC Input

Mains

AC Input

Mains

AC Input

8720MC-LR

xx 

Line Reactor

Circuit 

Protection

Circuit 

Protection

DC-bus Power Supplies in Parallel

2198-P208 DC-bus 

Power Supply

2198-P208 DC-bus 

Power Supply

8720MC-LR

xx 

Line Reactor

8720MC-LR

xx 

Line Reactor

Summary of Contents for Kinetix 5000

Page 1: ...ns for the AC line filters used with the Kinetix 5000 servo drive families For more information on installing and wiring your Kinetix 5500 or Kinetix 5700 servo drive refer to the drive family user ma...

Page 2: ...ith respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automat...

Page 3: ...rating Phasing of main AC power is arbitrary and earth ground connection is required to improve safety and proper operation ATTENTION To avoid personal injury or damage to equipment due to hazardous...

Page 4: ...rive input power IPD connections for three phase operation Line Load 2198 Pxxx DC bus Power Supply 2198 Hxxx ERSx Servo Drives 2198 H003 ERSx 2198 H008 ERSx 2198 H015 ERSx Servo Drives Mains Contactor...

Page 5: ...que Values N m lb in 2198 H003 ERSx 2198 DB08 F 2 2 Applies to installations with single phase or three phase input power 1 5 6 16 10 7 5 0 30 0 8 7 1 2198 H008 ERSx 2198 H015 ERSx 2198 H025 ERSx 2198...

Page 6: ...198 DB20 F AC Line Filter Dimensions catalog number 2198 DB42 F 6 0 0 24 R3 0 0 12 8 5 0 33 217 8 54 201 7 91 227 8 94 1 2 0 05 93 3 66 115 5 4 55 55 2 16 42 1 65 42 1 65 M5 Dimensions are in mm in 6...

Page 7: ...Line Filter Dimensions catalog number 2198 DB290 F 298 11 73 79 3 11 79 3 11 7 0 0 28 1 2 0 05 312 12 28 94 3 70 190 7 48 M8 Dimensions are in mm in 90 3 54 146 5 75 208 8 19 30 1 18 10 5 0 41 268 10...

Page 8: ...at No Voltage Rating Current Rating A 50 C 122 F Power Loss Rated Current W Leakage Current typ mA Weight approx kg lb Operating Temperature 2198 DB08 F 480V AC 1 three phase 50 60 Hz 1 Tolerance for...