Allen-Bradley Kinetix 5000 Installation Instructions Manual Download Page 2

2

     Kinetix 5000 AC Line Filters

Rockwell Automation Publication 2198-IN003B-EN-P - March 2015

Important User Information

Read this document and the documents listed in the additional resources section about installation, configuration, and operation of 
this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with 
installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.

Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be 
carried out by suitably trained personnel in accordance with applicable code of practice.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or 
application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and 
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual 
use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software 
described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is 
prohibited.

Throughout this manual, when necessary, we use notes to make you aware of safety considerations.

Labels may also be on or inside the equipment to provide specific precautions.

WARNING: 

Identifies information about practices or circumstances that can cause an explosion in a hazardous 

environment, which may lead to personal injury or death, property damage, or economic loss.

ATTENTION: 

Identifies information about practices or circumstances that can lead to personal injury or death, 

property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the 
consequence.

IMPORTANT

Identifies information that is critical for successful application and understanding of the product.

SHOCK HAZARD: 

Labels may be on or inside the equipment, for example, a drive or motor, to alert people that 

dangerous voltage may be present.

BURN HAZARD: 

Labels may be on or inside the equipment, for example, a drive or motor, to alert people that 

surfaces may reach dangerous temperatures.

ARC FLASH HAZARD: 

 Labels may be on or inside the equipment, for example, a motor control center, to alert 

people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective 
Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective 
Equipment (PPE).

Summary of Contents for Kinetix 5000

Page 1: ...ns for the AC line filters used with the Kinetix 5000 servo drive families For more information on installing and wiring your Kinetix 5500 or Kinetix 5700 servo drive refer to the drive family user ma...

Page 2: ...ith respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automat...

Page 3: ...rating Phasing of main AC power is arbitrary and earth ground connection is required to improve safety and proper operation ATTENTION To avoid personal injury or damage to equipment due to hazardous...

Page 4: ...rive input power IPD connections for three phase operation Line Load 2198 Pxxx DC bus Power Supply 2198 Hxxx ERSx Servo Drives 2198 H003 ERSx 2198 H008 ERSx 2198 H015 ERSx Servo Drives Mains Contactor...

Page 5: ...que Values N m lb in 2198 H003 ERSx 2198 DB08 F 2 2 Applies to installations with single phase or three phase input power 1 5 6 16 10 7 5 0 30 0 8 7 1 2198 H008 ERSx 2198 H015 ERSx 2198 H025 ERSx 2198...

Page 6: ...198 DB20 F AC Line Filter Dimensions catalog number 2198 DB42 F 6 0 0 24 R3 0 0 12 8 5 0 33 217 8 54 201 7 91 227 8 94 1 2 0 05 93 3 66 115 5 4 55 55 2 16 42 1 65 42 1 65 M5 Dimensions are in mm in 6...

Page 7: ...Line Filter Dimensions catalog number 2198 DB290 F 298 11 73 79 3 11 79 3 11 7 0 0 28 1 2 0 05 312 12 28 94 3 70 190 7 48 M8 Dimensions are in mm in 90 3 54 146 5 75 208 8 19 30 1 18 10 5 0 41 268 10...

Page 8: ...at No Voltage Rating Current Rating A 50 C 122 F Power Loss Rated Current W Leakage Current typ mA Weight approx kg lb Operating Temperature 2198 DB08 F 480V AC 1 three phase 50 60 Hz 1 Tolerance for...

Reviews: