Purpose

This demo is designed to demonstrate the features of a Multifunctional Access 

Box and the Guard Locking with Time Delay (GLT relay) Safety Relay.

Product Overview

The multifunctional access box is a guard locking interlock with integrated 

controls that helps facilitate access to a safeguarded area. The customer 

determines the functions of the integrated push buttons and the functions can 

vary depending on the application. For this demo, a push button has been 

assigned as an “Unlock Request” and the other one as a “Reset and Lock 

Request.” 

You press the Unlock Request button to request access to the safeguarded area. 

The control system (GLT relay) shuts down the hazard and unlocks the guard 

door after a time delay. Then you are allowed to open the guard door and enter 

the safeguarded area. Upon exiting the safeguarded area, you close the door and 

press the Reset and Lock Request button to lock the guard door and reset the 

safety system.

Guard Locking with Time-delay (GLT relay) Safety Relay

The GLT relay safety relay is designed to use time-delay outputs for use in 

Stop Category 1 applications and to unlock a guard door when the time 

expires. The relay also provides a lock command to lock a guard door before the 

starting of the hazard. In this demo, there is a three-second delay between the 

time that the GLT relay receives the Unlock Request and the time that the 

relay issues the Unlock command to the access box.

Summary of Contents for Guardmaster 442G-MABR-URM-C03

Page 1: ...Lock Request You press the Unlock Request button to request access to the safeguarded area The control system GLT relay shuts down the hazard and unlocks the guard door after a time delay Then you ar...

Page 2: ...800F Blue Push Button Reset GLT relay Relay Logic 2 Range 3 Time 6 SI Relay Automatic Manual Reset AM E stop Front View Rear View Escape Release A2 S12 S22 24 51 L61 B2 L12 L11 14 A1 S11 440R GL2S2T...

Page 3: ...gnals 5 Close the guard door The blue push button does not turn on again until you rotate the handle to insert the bolt into the lock module 6 To reset the safety system press the blue push button The...

Page 4: ...efault factory setting the system enters into a latchingfaultwhen the escape releaseis actuated If theescapereleaseis actuatedtooslowly the system will not enter into a latching fault 10 To reset the...

Page 5: ...to the circuit breaker to the power supply Note You can reconfigure the access box DIP switches to deactivate Release Monitoring refer to Chapter 4 Change Device Configuration use of DIP switches in 4...

Page 6: ...sms automatically extends when the handle is in the OPEN position The other mechanism is manually extended see Figure 1 To pivot out press the grooved part only possible with the handle in the OPEN po...

Page 7: ...Rockwell Automation Publication 442G DM001A EN P September 2015 7 Multifunctional Access Box and Guard Locking with Time Delay Safety Relay Notes...

Page 8: ...n com rockwellautomation about us sustainability ethics product environmental compliance page Allen Bradley and Guardmaster are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwe...