Allen-Bradley ArmorBlock 1732D A Series Installation Instructions Manual Download Page 16

Publication 1732D-IN001B-EN-E - May 2004 

16

PN 957899-53

Supersedes Publication 1732D-IN001A-EN-E - April 2004

Copyright © 2004 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Rockwell Automation Support

Rockwell Automation provides technical information on the web to assist you in using our products. At 
http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and 
application notes, sample code and links to software service packs, and a MySupport feature that you can customize 
to make the best use of these tools.

For an additional level of technical phone support for installation, configuration and troubleshooting, we offer 
TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation 
representative, or visit http://support.rockwellautomation.com.

Installation Assistance

If you experience a problem with a hardware module within the first 24 hours of installation, please review the 
information that's contained in this manual. You can also contact a special Customer Support number for initial help 
in getting your module up and running:

New Product Satisfaction Return

Rockwell tests all of our products to ensure that they are fully operational when shipped from the manufacturing 
facility. However, if your product is not functioning and needs to be returned:

United States

1.440.646.3223

Monday – Friday, 8am – 5pm EST

Outside United States

Please contact your local Rockwell Automation representative for any technical support 
issues.

United States

Contact your distributor.  You must provide a Customer Support case number (see phone 
number above to obtain one) to your distributor in order to complete the return process.

Outside United States

Please contact your local Rockwell Automation representative for return procedure.

 

ArmorBlock, RSNetWorx for DeviceNet, and DeviceNetManager are trademarks of Rockwell Automation.

 

DeviceNet is a trademark of Open DeviceNet Vendor Association.

Summary of Contents for ArmorBlock 1732D A Series

Page 1: ...Automation sales office or online at http www ab com manuals gi describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is ac...

Page 2: ...ons as defined in IEC publication 60664 1 at altitudes up to 2000 meters without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR Publication 11 Without appropriate precautions there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance This equipment is supplied a...

Page 3: ...e switches The two switches are X10 most significant digit left side of module X1 least significant digit right side of module To reset the node address use a small blade screwdriver to rotate the switches Line up the small black dot on the switch with the number setting you wish to use and then cycle power ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic d...

Page 4: ...ing red MOD LED Settings between 64 and 99 cause the module to use the last valid node address stored internally Example The last setting internally was 40 If a change is made to 68 and then you power up the address will default to 40 The module is equipped with AutoBaud detect AutoBaud lets the module read the settings already in use on your DeviceNet network and automatically adjusts to follow t...

Page 5: ...t are used to mount the module directly to a panel or machine The module can be front or side mounted Mounting holes accommodate 6 M3 pan head screws The torque specification is 6 in lbs 1 46in 37mm 67in 17mm 78in 19 8 mm 6 56in 166 5mm 6 64in 168 6mm 7 05in 179mm 1 06in 27mm 1 70in 43 3mm 1 26 in 32mm 9577597 101 Front Mounting Side Mounting ...

Page 6: ... Mount the flat and lock washer as shown in the following illustration Torque the mounting screws to 6 in lbs Connect the Input Output Cord Sets to the ArmorBlock Module The ArmorBlock family offers 5 pin micro style PCB mounting connectors or 3 pin pico style PCB mounting connectors We provide caps to cover the unused connectors on your module Connect the quick disconnect cord sets you selected f...

Page 7: ...Input A Pin 5 Not used Output Connector Cat Nos 1732D OB8EM12 view into connector Pin 1 Not Used Pin 2 Output B Pin 3 Return Pin 4 Output A Pin 5 Not Used 5 Pin Micro Style 12mm Female Connectors Input Connector Cat Nos 1732D IB8M8 view into connector Pin 1 Sensor Source voltage Pin 3 Return Pin 4 Input Output Connector Cat Nos 1732D OB8EM8 view into connector Pin 1 Not Used Pin 3 Return Pin 4 Out...

Page 8: ... reference the 889P products IMPORTANT If the devices sensors connected to the input connections require Class 2 power to operate the auxiliary power connections of this equipment must be powered by a Class 2 source ATTENTION Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP67 requirements MSD LSD DeviceNet Node Address 4 12mm o...

Page 9: ...tivation deactivation of sensors and actuators always wire input sensors and output actuators directly to the I O connectors Communicate With Your ArmorBlock I O Module This ArmorBlock module s I O is exchanged with the master through a poll change of state or cyclic connection Cyclic allows configuration of the block as an I O client The block will produce and consume its I O cyclically at the ra...

Page 10: ...be an output dedicate that point as an output with a wired load and energize it through a control program If an I O point is to be an input wire the input device as normal and leave the associated output un energized at all times 1732D IB8M12 and 1732D IB8M8 1732D OB8EM8 and 1732D OB8EM12 The DeviceNet Network uses advanced network technology producer consumer communication to increase network fun...

Page 11: ...rs Network and Module status indicator for DeviceNet Auxiliary Power indicator Individual I O status indicators for inputs and outputs I O Status Indicators M8 Style Connectors Module Indicator Network Indicator Auxiliary Power Indicator 43820 M12 Style Connectors I O Status Indicators Module Indicator Network Indicator Auxiliary Power Indicator 43821 ...

Page 12: ...he established state The device has passed the dup_MAC_id test is on line but has no established connections to other nodes As a Group 2 device it means that the device is not allocated to a master Critical link failure Solid Red Failed communication device The device has detected an error that has rendered it incapable of communication on the network dup_MAC_id failure or bus off Connection time ...

Page 13: ...icators Function Point Indicator Condition Outputs None Yellow Output not energized Output energized Inputs None Yellow No valid input Valid input DeviceNet 1732 ArmorBlock I O Series A Input Specifications Inputs 61131 2 Type 3 Compatible Sensor Source Current Maximum per input 50mA Sensor Source Current Maximum per module 400mA Sensor Source Voltage auxiliary power 12 30V dc Maximum Minimum 30V ...

Page 14: ...g Thermal Shock 20 to 60 C 4 to 140 F Storage Temperature IEC 60068 2 1 Test Ab Un packaged Non operating Cold IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat IEC 60068 2 14 Test Na Un packaged Non operating Thermal Shock 45 to 85 C 49 to 185 F Relative Humidity IEC 60068 2 30 Test Db Un packaged Non operating Damp Heat 5 95 non condensing Shock IEC60068 2 27 Test Ea Unpackaged Shock Oper...

Page 15: ...unity EN 61326 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity C Tick3 Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions ODVA ODVA conformance tested to DeviceNet specifications 1 You use this conductor category information for planning conductor routing as described in the system level installation manual 2 See pub 1770 4 1 Programmab...

Page 16: ...ce a problem with a hardware module within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your module up and running New Product Satisfaction Return Rockwell tests all of our products to ensure that they are fully operational when shipped from the manufacturing facil...