40
Rockwell Automation Publication 6181X-UM001C-EN-P - July 2015
Chapter 4
Component Replacement
If necessary, remove the existing CF card by sliding it out of the slot (F).
7.
Insert the new CF card into the slot (G) until it is firmly seated.
8.
Replace the CF card lock screw (H).
9.
Push in the CF card tray (I).
10.
Close the drive bay lever ( J).
11.
Tighten the screw that secures the drive bay lever (K).
ATTENTION:
When properly seated, more than 80% of the CF card easily
inserts into the slot before you encounter resistance. If you encounter
resistance sooner, then remove the card, rotate it 180°, and reinsert.
Do not force the card into the slot or you can damage the connector pins.
WARNING:
You must reinstall the CF card lock screw to meet hazardous
locations, mechanical shock, and vibration requirements.
F
C
E
A
B
D
Display Computer Shown