8
Industrial Integrated Display Computers with Keypad
Rockwell Automation Publication 6180P-IN001C-EN-P - July 2013
7.
Hand-tighten the mounting clips around the bezel by following the tightening sequence
shown below.
8.
Repeat this process at least three times until the clips are hand-tight and the gasket is
compressed uniformly against the panel.
9.
Tighten the mounting clips to a torque of 1.4 N•m (12 lb•in) by following the specified
torque sequence shown below, being sure to not overtighten.
ATTENTION:
Tighten the mounting clips to the specified torque to provide a proper seal and
prevent damage to the product. Rockwell Automation assumes no responsibility for water or
chemical damage to the product or other equipment within the enclosure because of improper
installation.
8
Torque Sequence for 1200P and 1500P Computers
1
7
5
2
6
9
3
4
10