Industrial Integrated Display Computers with Keypad
7
Rockwell Automation Publication 6180P-IN001C-EN-P - July 2013
Panel Cutout Dimensions
The 6180P products must be appropriately mounted in the panel cutout specified below.
Mount the Display Computer in a Panel
Mounting clips secure the computer to the panel. The 1200P and 1500P both require 10
mounting clips. Follow these steps to mount the computer in a panel.
1.
Remove power from the panel before making the cutout.
2.
Verify that the panel surface around the area to be cut is clean and free of debris.
3.
Cut an opening in the panel using the appropriate panel cutout dimensions.
4.
Make sure the sealing gasket is properly positioned on the computer.
This gasket forms a compression-type seal. Do not use sealing compounds.
5.
Place the computer in the panel cutout.
6.
Slide the mounting clips into the slots on the top, bottom, and sides of the computer.
Model
Cut-out Dimensions (HxW), approx.
1200P
279.0 x 450.0 mm (10.98 x 17.72 in.)
1500P
326.4 x 429.3 mm (12.85 x 16.90 in.)
ATTENTION:
Take precautions so metal cuttings do not enter components already
installed in the panel to avoid personal injury or damage to the panel components.