background image

Publication 6180P-IN001C-EN-P - July 2013

PN-98850

DIR 10000146675 (Version 01)

Supersedes Publication 6180P-IN001B-EN-P - April 2011

Copyright © 2013 Rockwell Automation, Inc. All rights reserved. Printed in China.

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its products. 
At 

http://www.rockwellautomation.com/support

, you can find technical manuals, technical and application notes, sample code and 

links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. You can also visit 
our Knowledgebase at 

http://www.rockwellautomation.com/knowledgebase

 for FAQs, technical information, support chat and 

forums, software updates, and to sign up for product notification updates.

For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect

SM

 

support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit 

http://www.rockwellautomation.com/support/

.

Installation Assistance

If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. 
You can also contact a special Customer Support number for initial help in getting your product up and running.

New Product Satisfaction Return

Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing 
facility. However, if your product is not functioning and needs to be returned, follow these procedures.

Documentation Feedback 

Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, 
complete this form, publicatio

RA-DU002

, available at 

http://www.rockwellautomation.com/literature/

.

United States or Canada

1.440.646.3434

Outside United States or 
Canada

Use the 

Worldwide Locator

 at 

http://www.rockwellautomation.com/rockwellautomation/support/overview.page

, or contact your 

local Rockwell Automation representative.

United States

Contact your distributor. You must provide a Customer Support case number (call the phone number 
above to obtain one) to your distributor to complete the return process.

Outside United States

Please contact your local Rockwell Automation representative for the return procedure.

Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Summary of Contents for 6180P-12BPXP

Page 1: ...t User Information 2 Environment and Enclosure Information 3 European Union Directive Compliance 3 Installation Guidelines 4 Operating Systems 4 Before You Begin 5 Before You Begin 5 Install the Compu...

Page 2: ...any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation I...

Page 3: ...t be mounted in an enclosure that is suitably designed to prevent personal injury resulting from accessibility to live parts If not mounted inside another enclosure the mounting method must limit thet...

Page 4: ...erfere with other equipment OperatingSystems The computers are shipped with Microsoft licensed Windows XP Professional Service Pack 3 operating system installed and configured No operating system upda...

Page 5: ...uter is shipped with these items Mounting hardware specific to each product Power cord AC IEC320 13 AC power option only Ground bus strip DC power option only Panel mount clips 10 Panel cut out templa...

Page 6: ...stallation Take precautions so metal cuttings do not enter components already installed in panel Supporting panels must be at least 14 gauge to ensure proper sealing against water and dust and to prov...

Page 7: ...surface around the area to be cut is clean and free of debris 3 Cut an opening in the panel using the appropriate panel cutout dimensions 4 Make sure the sealing gasket is properly positioned on the...

Page 8: ...formly against the panel 9 Tighten the mounting clips to a torque of 1 4 N m 12 lb in by following the specified torque sequence shown below being sure to not overtighten ATTENTION Tighten the mountin...

Page 9: ...P July 2013 ProductDimensions Product dimensions for each display computer model are given in mm in 483 19 0 225 8 9 274 10 8 445 17 5 427 16 8 1200P Integrated Display with Keypad 311 12 2 215 8 5 4...

Page 10: ...s Peripheral components compatible to each port are marked inside the callout figures The 1200P and 1500P computers have USB ports on both the I O port side panel and the front access door You can use...

Page 11: ...d terminals together This is to support SELV cases where the end user requires grounding at the computer The power supply is internally protected against reverse polarity ATTENTION Connect the AC powe...

Page 12: ...power wires to the terminal block screws 2 Secure the ground wire to the GND terminal block screw 3 Apply 24V DC power to the computer FunctionalGroundScrew The use of the functional ground screw is n...

Page 13: ...retain system information when power is removed The 3V 200 mAh lithium battery is on the system board IMPORTANT To prevent performance degradation of Ethernet communication do not subject the compute...

Page 14: ...attery socket 5 Remove the battery a Insert a small flat blade screwdriver between the battery and spring latch to dislodge the battery from its socket ATTENTION A risk of fire and chemical burn exist...

Page 15: ...expansion boards peripherals board covers and system cables that have previously been removed d Reinstall the back cover e Connect all external cables and the AC power cord to the computer f Press the...

Page 16: ...acking material ATTENTION The backlight assembly in this unit contains mercury At the end of its life this equipment should be collected separately from any unsorted municipal waste ATTENTION Do not s...

Page 17: ...tive resolution 1200P 1500P 800 x 600 1024 x 768 Viewing angle Horizontal Vertical 60 40 Response time 20 ms Electrical Input voltage AC 90 264V AC autoswitching Line frequency 47 63 Hz Power consumpt...

Page 18: ...11 ms Shock nonoperating 30 g 1 2 sine 11 ms Certifications Regulatory Area Standards Group Regulatory Standard Americas Safety requirements UL 60950 1 CSA C22 2 60950 1 Emissions requirements FCC Ru...

Page 19: ...rated Display Computer with Keypad user manual publication number 6180P UM001 Overview of the system and description of procedures for installation connections configuration and troubleshooting Clonin...

Page 20: ...so contact a special Customer Support number for initial help in getting your product up and running NewProductSatisfactionReturn Rockwell Automation tests all of its products to help ensure that they...

Reviews: