background image

4

Rockwell Automation Publication VIEW-IN002C-EN-P - October 2018

Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals

Remove the Existing Terminal From the Panel

Follow these steps to remove the existing terminal from the panel.

1.

Remove all power from the enclosure and the terminal.

2.

Disconnect all communication cables from the terminal.

3.

While holding the terminal, remove the mounting clamps that secure the terminal in the 
panel.

4.

Remove the terminal from the panel.

Drill the Holes for the Adapter Kit

Follow these steps to drill the holes for the adapter kit by using the drill template included in this 
kit.

1.

Clean the panel where the drill template will be taped over the existing cutout.

2.

Determine which side of the drill template that you need.

ATTENTION: 

Remove all power from the components in the enclosure and the existing terminal. 

Disconnect the communication cables from the terminal.

Failure to remove all power and disconnect communication cables can cause electric shock and 
unexpected communication signals to the machinery.

ATTENTION: 

Be careful when removing the mounting clamps. The terminals can fall out of the 

panel after the mounting clamps have been removed. Be sure to hold the terminal in the panel 
while you remove the mounting clamps, and then carefully remove the terminal from the panel.

Drill Template for PanelView™ 5000 and PanelView Plus 7 Performance 

JO

Terminals Adapter Kit

For Adapter Kit 2711P-RAAK7

Drill Template for PanelView 5000 and PanelView Plus 7 Performance Terminals

6.5-in. Keypad with Touch Screen Adapter Kit

Replaces these Existing Terminals:

PanelView Plus 6 700 Keypad, or Keypad with Touch Screen

PanelView Standard 600 Keypad, or Keypad with Touch Screen

Printed Actual Size (scale = 1:1)

If you print this drill template from the PDF file, set the paper size on your plotter or printer to 18 x 12 inches.

For dimensions, see the Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals

Installation Instructions, publication 

VIEW-IN002

, which is shipped with this drill template.

Identifies the new terminals 
that can be installed with 
this drill template.

Identifies the existing 
terminals that can be 
replaced with this drill 
template.

Summary of Contents for 2711P-RAAK10

Page 1: ...he ExistingTerminal From the Panel 4 Drill the Holes for the Adapter Kit 4 Install the Adapter Plate and Backing Plate 6 Prepare to Mount theTerminal 8 Mount theTerminal 9 Finish theTerminal Installat...

Page 2: ...dapter Kit Cat No Replace this Existing PanelView Plus 6 or PanelView Standard Terminal With this PanelView 5000 or PanelView Plus 7 Performance Terminal Uses Drill Template Cat No 2711P RAAT7 PanelVi...

Page 3: ...2 Drill template These installation instructions RequiredTools These tools are required for installation Clean cloth and a suitable cleanser for dirty panels Masking tape and marker or grease pencil S...

Page 4: ...and unexpected communication signals to the machinery ATTENTION Be careful when removing the mounting clamps The terminals can fall out of the panel after the mounting clamps have been removed Be sure...

Page 5: ...in drill bit 10 To drill the finish holes use the 6 35 mm 1 4 in drill bit 11 Remove any burrs from the drilled holes 12 Remove all drill shavings from inside the enclosure and the vicinity 13 Remove...

Page 6: ...on the adapter plate and is not damaged This gasket forms a compression seal Do not use sealing compounds 3 From the front of the panel insert the threaded studs of the adapter plate through the hole...

Page 7: ...tomation is not responsible for water or chemical damage to the terminal or other equipment within the panel due to improper installation Adapter Plate withThreaded Studs and Gasket Installed on Front...

Page 8: ...ence Mounting Lever Orientation and Lock Sequence IMPORTANT The mounting lever orientations that are shown are required to maintain NEMA ULType and IP seals If you require a NEMA ULType or IP seal do...

Page 9: ...ert adapter kit mounting levers in the top corner slots by using the orientation in Mounting Lever Orientation and Lock Sequence on page 8 The example at right shows the top of a 6 5 in touch screen t...

Page 10: ...de the mounting lever to the final locking position If it is too difficult to slide a mounting lever to its final locking position then slide the mounting lever one position at a time until you are ab...

Page 11: ...ons in the user manual for your terminal PanelView 5310 Terminals User Manual publication 2713P UM001 PanelView 5500 Terminals User Manual publication 2715 UM001 PanelView 5510 Terminals User Manual p...

Page 12: ...locations of the adapter kit 6 5 in Only Touch Catalog Number 2711P RAAT7 6 5 in Keypad and Touch Catalog Number 2711P RAAK7 220 8 66 154 6 06 18 5 0 73 18 0 7 257 10 11 NOTE All dimensions are in mm...

Page 13: ...AAT10 10 4 in Keypad and Touch Catalog Number 2711P RAAK10 305 12 0 224 8 82 17 5 25 0 98 274 10 78 340 13 39 112 4 4 95 3 74 120 5 4 74 279 5 11 0 95 3 74 95 3 74 95 3 74 NOTE All dimensions are in m...

Page 14: ...12 12 1 in Only Touch Catalog Number 2711P RAAT12K 338 13 31 257 10 12 43 5 1 71 18 0 71 128 5 5 06 21 0 83 169 6 65 95 3 74 359 14 13 380 14 96 293 11 54 95 3 74 95 3 74 95 3 74 6 35 0 25 NOTE All di...

Page 15: ...pad and Touch Catalog Number 2711P RAAK15 391 15 39 305 12 0 18 0 71 26 5 1 04 444 17 48 341 13 43 152 5 6 0 95 3 74 95 3 74 195 5 7 70 375 5 14 78 15 5 0 61 85 3 35 85 3 35 6 35 0 25 NOTE All dimensi...

Page 16: ...blication 2713P TD001 Provides technical specifications environmental specifications and certifications for the PanelView 5310 terminals PanelView 5500Terminals User Manual publication 2715 UM001 Prov...