Publication 2707-UM005B-EN-P
MicroView Special Controller Functions
C-7
Reading / Writing
Controller Counter Files
To read/write the contents of controller Counter files:
There are two types of counter files supported by the MicroLogix
controller. Element 0 (Zero) is for the MicroLogix high speed counter.
Elements 1 to 31 are for the standard MicroLogix counter. You can
read/write the accumulator and preset values of the counter. You can
not edit the status bit data files. They are read-only.
Refer to the MicroLogix User Manual for a complete description of
high speed counter status bits.
1.
Press [1] P-A/D from the Special Menu to access the P-A/D
function.
2.
Press [NEXT] and [PREV] keys to scroll through the file types.
Select Counter and press [
].
3.
You are prompted for an element number:
4.
Enter the element number and press [
]. You are shown the
counter accumulator value
5.
Press [NEXT] to display the counter preset value:
6.
You can change the Acc and Pre values by pressing the [PREV]
or [NEXT] keys to move the cursor to the field to change, and
then entering a new value.
Select File Type:
O (Output)
Elem=___________
Accumulator
Accumulated Value
File=C5
Elem=010
02000
Acc
Preset
Preset Value
File=C5
Elem=010
02500
Pre
Summary of Contents for 2707-MVH232
Page 1: ...MicroView Operator Interface Module Catalog No 2707 MVH232 2707 MVP232 User Manual...
Page 6: ...Publication 2707 UM005B EN P Table of Contents iv...
Page 28: ...Publication 2707 UM005AB EN P 3 12 Initial Setup and Mode Menu...
Page 50: ...Publication 2707 UM005B EN P July 2000 6 6 Installing the MicroView Operator Interface...
Page 54: ...Publication 2707 UM005B EN P 7 4 Communication Connections and Setup...
Page 70: ...Publication 2707 UM005B EN P A 2 Specifications...
Page 74: ...Publication 2707 UM005B EN P B 4 MicroView Cable Diagrams...
Page 91: ...B...