Publication 2707-UM005B-EN-P
Microview Overview
2-7
Upload/Download Connections
For programming and configuration, the MicroView is connected to
your computer’s RS-232 port using a programming cable (Catalog No.
2707-NC8). See Appendix B if you need to construct your own cable.
Upload/Download Connections
Default Settings
The MicroView is preset at the factory with these defaults:
Operating Parameters
- The default operating functions are shown
in the table below. The operating functions can be set using the
MicroView Mode Menu. Refer to Chapter 3.
Operating System -
The MicroView is provided with a default
application file using the MicroLogix DF1 operating system. The
application file displays the message:
Programming Controller
MicroView Operator Interface
Com 1 or Com 2
RS-232
Power Supply
(Upload/Download Only)
Programming Cable
Catalog No. 2707-NC8 or
1761-CBL-PM02
Function
Parameter
Default Value
Com-Port
Baud
9600
Data Bits
8 (Fixed)
Parity
None (Fixed)
Other
Simulate
Off
Master Code
00000000 (All zeros)
Scale
On
No Application
Program Loaded
Summary of Contents for 2707-MVH232
Page 1: ...MicroView Operator Interface Module Catalog No 2707 MVH232 2707 MVP232 User Manual...
Page 6: ...Publication 2707 UM005B EN P Table of Contents iv...
Page 28: ...Publication 2707 UM005AB EN P 3 12 Initial Setup and Mode Menu...
Page 50: ...Publication 2707 UM005B EN P July 2000 6 6 Installing the MicroView Operator Interface...
Page 54: ...Publication 2707 UM005B EN P 7 4 Communication Connections and Setup...
Page 70: ...Publication 2707 UM005B EN P A 2 Specifications...
Page 74: ...Publication 2707 UM005B EN P B 4 MicroView Cable Diagrams...
Page 91: ...B...