Chapter 3
Programming and Parameters
d311 [Fault 1 Time-min]
Displays the value of the
[Elapsed Time-min] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d312 [Fault 2 Time-hr]
Displays the value of the
[Elapsed Time-hr] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d313 [Fault 2 Time-min]
Displays the value of the
[Elapsed Time-min] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d314 [Fault 3 Time-hr]
Displays the value of the
[Elapsed Time-hr] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d315 [Fault 3 Time-min]
Displays the value of the
[Elapsed Time-min] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d316 [Elapsed Time-hr]
,
Displays the total elapsed powered-up time (in hours) since timer reset. The timer stops when it reaches maximum.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d317 [Elapsed Time-min]
,
Displays the total elapsed powered-up time (in minutes) since timer reset. The timer will increment the hour parameter when appropriate.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d318 [Output Powr Fctr]
Related Parameter(s):
,
,
The angle in electrical degrees between motor voltage and motor current.
Values
Default:
Read Only
Min/Max:
0.0/180.0 deg
Display:
0.1 deg