Rockwell Automation Publication 20Y-TG001C-EN-P - April 2017
81
LCL Filter Component Section
Chapter 7
4. Remove the X52 terminal block from the LCL filter assembly (upper
right side).
5. Remove the four T25 Torx self-tapping screws that secure the front
bracket that is shown in
.
This bracket holds the LCL filter in the enclosure.
6. Disconnect the AC input bus bars (L1, L2, L3) between the MCCB and
LCL filter.
For bus bar locations, see
.
7. Disconnect the output bus bars (U, V, W) between the LCL filter and
the AFE power structure.
For bus bar locations, see
.
8. Slide the LCL filter out of the enclosure.
Install the LCL Filter in the
Enclosure
Install the LCL filter in reverse order of removal. See
.
ATTENTION:
The LCL filter is heavy. To avoid personal injury or
damage to the equipment, use caution when removing the LCL filter
from the enclosure.
IMPORTANT
Ramps (customer-supplied) can be required due to enclosure floor
mismatch.
LCL Filter
Removed from Enclosure