78
Rockwell Automation Publication 20Y-TG001C-EN-P - April 2017
Chapter 7
LCL Filter Component Section
Replace the LCL Filter Fan
To replace the LCL filter fan, follow these steps.
1. Remove the LCL filter protective barrier.
Remove the LCL Filter Protective Barrier on page 74
2. Disconnect terminal blocks X51 and X53.
3. Remove the two 10 mm hexagonal bolts.
4. Lower the front fan sheet metal edge and slide it forward to remove the
alignment studs from their respective holes in the fan frame sheet metal.
5. Slide out the fan assembly.
6. Remove the LCL filter fan DC power supply.
Remove the LCL Filter Fan DC Power Supply on page 75
7. Reinstall the LCL filter fan in reverse order of removal. See
Note the LCL filter airflow cooling requirements.
Remove the LCL Filter
The procedures to remove the LCL filter are slightly different depending on
the enclosure in which it is installed.
LCL Filter
Required Airflow
LCL 460
1100 m
3
/hr
LCL 1300
1300 m
3
/hr
X51
X53
Hexagonal
Bolt Location
LCL Filter
Right-side View