background image

                    

 FLEX Ex Spring Clamp Terminal Base

5

 1797-5.2 - September 1999

2. Check to make sure that the 16 pins in the male connector on the 

adjacent device are straight and in line so that the mating female 
connector on this terminal base unit will mate correctly.

3. Make certain that the female flexbus connector is fully retracted into 

the base unit.

4. Position the terminal base over the 35 x 7.5mm DIN rail A 

(A-B pt. no. 199-DR1).

!

ATTENTION:  Do not force the terminal base into the 
adjacent modules. Forcing the units together can bend or break 
the hook and allow the units to separate and break 
communication over the backplane.

A

A

41114

Position terminal base at a slight angle and 
hooked over the top of the DIN rail A.

41115

Slide the terminal base over tight against the adapter (or proceeding terminal 
base). Make sure the hook on the terminal base slides under the edge of the 
adapter and the flexbus connector is fully retracted.

Allen-Bradley

Summary of Contents for 1797-TB3S

Page 1: ...er wiring the terminal base unit Component Identification 1 Female flexbus connector 2 Terminal base unit 3 Male flexbus connector 4 Keyswitch Set to the position required for the installed module 5 M...

Page 2: ...n be cut out and posted is included in this installation instruction European Community Directive Compliance If this product has the CE mark it is approved for installation within the European Communi...

Page 3: ...e followed The terminals in this terminal base unit may be electrically connected to each other by the insertion of FLEX Ex I O modules See the module installation instructions to determine this Descr...

Page 4: ...supply Do not exceed the values listed in the specifications for this terminal base unit Do not use the unused terminals on this terminal base unit Using these terminals as supporting terminals can re...

Page 5: ...base over the 35 x 7 5mm DIN rail A A B pt no 199 DR1 ATTENTION Do not force the terminal base into the adjacent modules Forcing the units together can bend or break the hook and allow the units to s...

Page 6: ...terminal base is in place Wiring 1 Make wiring connections as described in the installation instructions included with the specific module that mounts on your terminal base unit 2 Connect V and V fro...

Page 7: ...intended operation of your system Daisy chaining 41110 V V Wiring when total module current power is less than 8 5W Combination Wiring when total module current power is greater than 8 5W 41111 V V 8...

Page 8: ...unit will void the warranty and IS certification If repair is necessary return this module to the manufacturer About the Mounting Kit Use the optional 1794 NM1 mounting kit to mount your system on a p...

Page 9: ...d by inserted module Weight 200g approximately Dimensions with module installed in base Inches Millimeters 3 7H x 3 7W x 2 7D 94H x 94W x 69D Environmental Conditions Operational Temperature Storage T...

Page 10: ...5 5 2 3 58 5 1 4 35 5 1 6 40 5 61 15 6 3 8 Cable length approximately 11 5 292 1 or 35 5 901 0 from upper connector length depends upon cable 1ft 0 3m or ATTENTION Be careful of metal chips when drill...

Page 11: ...amp Terminal Base 11 1797 5 2 September 1999 Important For detailed certification information refer to the FLEX Ex System Certification Reference Manual publication 1797 6 5 6 Attention Avoid electros...

Page 12: ...Publication 1797 5 2 September 1999 PN 957208 15 Supersedes Publication 1797 5 2 September 1998 1999 Rockwell International All Rights Reserved Printed in USA...