4 Initial operation
© 2022 Interflex Datensysteme GmbH | IF-4735 Time Recording Terminal | 04.22
21
Use the cold boot during initial operation and in the event of malfunctions that cannot be
remedied by other means, e.g., a warm boot.
1. Set switches:
2. Shortly press the Reset button
3. Wait until the RUN LED lights up again permanently (procedure can take up to 45 seconds)
4. Reset switch position:
Associated console command:
oc -c
oder
factory-reset application
Reset network settings to factory default
The network settings are reset.
1. Set switches:
2. Shortly press the Reset button
The previous network settings are
not
saved temporarily, unlike in earlier variants.
Factory reset
All factory settings are restored.
For initial operation, the controller can then only be accessed via a serial console or the IF-
ServiceApp.
1. Set switches:
2. Shortly press the Reset button
3. Wait until the RUN LED lights up again (procedure can take up to 30 seconds)