23
Owner’s Manual
Compressor (cont’d)
MAINTENANCE
WARNING!
TO AVOID PERSONAL INJURY, ALWAYS SHUT OFF AND
UNPLUG THE COMPRESSOR AND RELIEVE ALL AIR PRESSURE FROM THE
SYSTEM BEFORE PERFORMING ANY SERVICE ON THE AIR COMPRESSOR.
LUBRICATION:
This air compressor requires regular lubrication for operation.
NOTE:
Use air compressor oil such as SAE 10W-20. Under extreme winter
conditions use SAE-10 oil. You may also use mobile 1 synthetic 10W-30 oil. Drain and
refill the compressor oil after the first 100 hours of operation.
CAUTION:
Compressors are shipped without oil. A small amount of oil may
be present in the pump upon receipt of the air compressor. DO NOT ATTEMPT TO
OPERATE THIS AIR COMPRESSOR WITHOUT FIRST ADDING OIL TO THE
CRANKCASE. Serious damage can result from even limited operation unless filled
with oil and broken in correctly. Follow initial start-up procedures closely. Damage
caused by failure to add oil will void your warranty.
WARNING!
Drain tank to release air pressure before removing the oil fill cap
or drain plug. Not doing so could result in serious damage to the compressor as well
as serious injury.
Place unit on a level surface. Remove oil fill plug and slowly add compressor oil. The
oil should be filled to the middle of the oil level window (see below).
When filling the crankcase, the oil flows very slowly into the pump .If the oil is added
too quickly, it will overflow and appear to be full. Crankcase oil capacity is
approximately 16 fluid ounces. Replace oil fill plug.
Drain and refill the compressor oil after the first 100 hours of operation then every 300
hours of use.
The oil should be filled
to the middle of the oil
level window.
OIL
OIL LEVEL WINDOW
24
Owner’s Manual
Compressor (cont’d)
MAINTENANCE (cont’d)
Relieve the air pressure in the system and open the petcock on the
bottom of the tank to drain.
WARNING!
CONDENSATION WILL ACCUMULATE IN THE TANK. TO
PREVENT CORROSION OF THE TANK FROM THE INSIDE, THIS MOISTURE
MUST BE DRAINED AT THE END OF EVERY WORKDAY, BE SURE TO WEAR
PROTECTIVE EYE WEAR.
Note:
In cold climates, drain the tank after each use to reduce problems with
freezing of water condensation.
Testing for Leaks
Check that all connections are right. A small leak in any of the hoses or pipe
connections will substantially reduce the performance of your air compressor. If you
suspect a leak, spray a small amount of soapy water with spray bottle. If bubbles
appear, repair or replace the faulty component. Do not over tighten any connections.
Storage
Before storing the compressor for a prolonged period, use an air blow gun to clean all
dust and debris from the STORAGE compressor. Disconnect the power cord and coil
it up. Pull the pressure relief valve, release all pressure from the tank. Drain all moisture
from the tank. Cover the entire unit to protect it from moisture and dust.
Servicing
Perform the following maintenance at the intervals indicated below:
• Operate the pressure relief valve:
Daily
• Drain air from tank:
Daily
• Change oil every 300 hours.