Fault finding table 

Trouble 

Action 

Burner does not light. 

 

Check if gas valve of the gas cylinder or gas line is open 

 

Check if gas cylinder is empty 

 

First ignition will take up to 60 or more seconds before gas is available 

 

Check if the injector is blocked 

 

Check if the gas pressure/gas quality is identical to the pressure 
indicated on the data plate  

Burner extinguishes 
after lighting  

 

Keep button safety device pressed for a longer period (up till 25 
seconds) 

 

Check if the thermocouple is connected properly to the gas safety 
device 

 

Check if the thermocouple tip is close to the flame 

 

Thermocouple or magnetic coil of the safety device is broken. 

 

Gas pressure lower than minimum requested 

 

Heater not suspended at 15 degrees angle 

Flames leave the 
- confines of the burner, 
- or are sooting, 
- or a blue cloud is 
under the reflector 

 

Gas pressure is too high. Check the gas pressure with the data plate 

 

Check if the gas pressure regulator is broken. 

 

Wrong gas is used. Check data plate for the correct gas supply 

 

Venturi/air inlet is blocked/dirty 

 

Check the size of the venturi and injector with the table 

 

Not enough fresh air available due to mounting situation 

 

Air filter is dirty 

 

Heater not suspended at 15 degrees angle 

The burner is only partly 
glowing 

 

Wrong gas or pressure is used. Check data plate with the gas supply 

 

Check if the injector or venturi are blocked or dirty 

 

Check the injector and venturi size with the table 

 

Check if pipe sizes or gas hoses have sufficient capacity 

 

Check the setting of the thermostat 

The burner makes a lot 
of noise after ignition or 
after several minutes 

 

Wrong gas is used. Check data plate with the gas supply 

 

Check if the venturi gauze is broken or damaged so the flame burns 
inside the venturi tube 

The burner does not 
work at minimum 
position 

 

Gas pressure is not correct. Check the gas pressure with the data plate 

 

Wrong gas is used. Check data plate for the correct gas supply 

 

Check the size of the venturi and injector with the table 

 

Sensor or wire thermostat is broken 

 

Thermostat valve adjusting mechanism is blocked 

Heater will not attain the 
desired temperature 

 

There is insufficient heat in the building for heat loss (i.e., not enough 
brooders). 

 

The thermostat sensing bulb is incorrectly placed 

 

The thermostat is out of calibration or broken 

 

Declaration of conformity 

We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that the AP series, marked 
on their data plates with CE and with CE approval/production supervision by Kiwa (number 0063) are in 
compliance with the following EU legislation: 
 

Directive on appliances burning gaseous fuels (GAD) 2009/142/EC (ex 90/396/EEC) 

Regulation on appliances burning gaseous fuels (GAR) 2016/426/EU 

 
Scherpenzeel, 01-04-2018 

 

Adri van Alphen  
President 
 

Summary of Contents for AP-1 Series

Page 1: ...infra red heaters for use in well ventilated areas Country of destination GB IE MT General international manual AP 1 AP 3 AP 2 AP 1 F AP 3 F AP 3 FT AP 2 F AP 2 FT Alke BV Industrielaan 11a 3925 BD S...

Page 2: ...t so that nobody accidentally operates the heater Store the heater in a safe place mark that it cannot be used and contact a service agent or gas installer to solve the problem This heater has an open...

Page 3: ...nature of gas and pressure and adjustment of the appliance are compatible Make sure that the gas and gas line are clean Install a gas filter and condensate trap before the heaters in case the gas or...

Page 4: ...for more details Beside other important requirements this standard states in short that a 1 5 times room air replacement per hour is sufficient in most situations Also a maximum of 5W heat input per...

Page 5: ...the gas supply to the burners to extinguish the flames In addition it makes it possible to remove the heaters after use or to service the heaters safely The gas inlet at the heater side is standard a...

Page 6: ...and away from other people Check if there are no other operating heaters other gas heaters burning candles or people smoking cigarettes in the area Be sure that the valve on the gas cylinder is close...

Page 7: ...ly one pressure is mentioned adjustment is not possible and only continuous operation or on off operation is allowed AP 1 2 3 FT version Make sure that the gas supply pressure remains constant at the...

Page 8: ...r gas tightness with leak detection liquid or soapy water according the procedure in the standards applicable in the local installation situation Never use a flame for soundness checks In case a gas h...

Page 9: ...he gas safety device are the most important parts that maybe requires replacement during normal operational life See the Parts List for more information Replacement thermocouple and magnet unit positi...

Page 10: ...ing Wrong gas or pressure is used Check data plate with the gas supply Check if the injector or venturi are blocked or dirty Check the injector and venturi size with the table Check if pipe sizes or g...

Page 11: ...2510000 Burner AP 3 50x80 mm 7 07009000 Distance ring 26 03856000 Suspension frame 155mm AP 2 8 01301000 Injector holder 27 013070xx Venturi 25x62 consult factory 9 01161xxx Injector M8x0 75 consult f...

Page 12: ...x x I3P G31 1400 20 5 6 0 65 T 1 2 400 g h 0 47 0 22 10 5 1 0063CS3936 I3P G31 1400 20 4 6 0 55 329 g h 0 45 x 11 4 x Ha 1400m I3P G31 2000 20 5 4 0 5 T 1 4 386 g h 0 41 0 22 10 4 x x AP 3 series I2L...

Reviews: