The display shows:
Program additional landings into the
system in the same manner.
NOTE!
– As soon as a landing is programmed into the controller it
unlocks intended door(s) on corresponding landings.
– If a VFC lift is in programming mode, then the driving speed
is very low in order to facilitate stopping at the landing level
intended to be programmed.
Should there be a longer distance between the landings it is
always possible to drive to the next landing in a higher speed
according to the following:
Press the Up button and wait
until the car has left the landing door zone – then press the
Up button once again. The system will then automatically
change to higher speed when running to the next landing.
Release the Up button and press the Stop Next Landing
button at the next landing level and the landing level will be
stored.
If the landing level needs to be adjusted, this must be done in
low speed mode.
– It is not possible to program a new landing in-between two
existing landings.
Delete the top landing:
Run the lift to the top landing in Normal operation mode.
The display shows:
(if the top landing is No. 5).
– Press the Prog. button on the car CPU and keep it depressed.
After approximately 3 seconds the Prog. LED will illuminate.
Then press Up and Down button at the same time. Then
release all buttons and the Prog. LED goes out.
The top landing level is now deleted and the system returns
to normal operation.
The display shows:
ALIMAK 34832 - 1 /04
A
29
1 lights up on the display
for the single system.
5 lights up on the display
for the single system.
Press Up-button once again
to achieve increased speed.
4 lights up on the display
for the single system.
+
Summary of Contents for ALC II
Page 1: ...Access anytime anywhere ALIMAK ALC II User s manual Original instructions ...
Page 2: ......
Page 8: ...This page is intentionally left blank A2 ...
Page 19: ...ALIMAK 34823 1 03 A13 Car CPU main unit ...
Page 50: ...A44 ...
Page 61: ......