A
LIEN
R
EADER
P
ROTOCOL
C
HAPTER
4
R
EADER
I
NTERFACE
G
UIDE
D
OC
. C
ONTROL
# 8101938-000 R
EV
05
78
The value can range from 0 to 32767.
The default value is 3 retries.
The period between retries is given by the NotifyRetryPause (below).
NotifyRetryCount Examples
Command
Response
>get NotifyRetryCount
NotifyRetryCount = 3
Command
Response
>set NotifyRetryCount = 0
NotifyRetryCount = 0
NotifyRetryPause
9800 | 9780 | 8780 | 9640 |
9774
When the reader attempts to send a network notification and fails, it tries again a
number of times specified by NotifyRetryCount. The time period between these
retries is specified by the NotifyRetryPause.
The value can range from 0 to 32767 seconds.
The default value is 10 seconds.
NotifyRetryPause Examples
Command
Response
>get NotifyRetryPause
NotifyRetryPause (secs) = 10
Command
Response
>set NotifyRetryPause = 60
NotifyRetryPause (secs) = 60
NotifyNow
9800 | 9780 | 8780 | 9640 |
9774
The NotifyNow command instructs the reader to send out an immediate
notification of its TagList to the address currently set by the NotifyAddress
command.
NotifyNow Examples
Command
Response
>NotifyNow
Issuing Notify Trigger...
Summary of Contents for ALR-8780