A
LIEN
R
EADER
P
ROTOCOL
C
HAPTER
4
R
EADER
I
NTERFACE
G
UIDE
D
OC
. C
ONTROL
# 8101938-000 R
EV
05
60
AcqCount
9800 | 9780 | 8780 | 9640 |
9774
AcqCount takes a single integer parameter between 1 and 255. It is the number
of reads (Global Scroll or Inventory) that are performed in each Class1 / Gen1
acquisition cycle. The default value for AcqCount is 3.
For example, if AcqCount is set to 10, then ten acquisition commands are issued
during each acquisition cycle.
NOTE: Changes made with this command will take effect immediately.
AcqCount Examples
Command
Response
>set AcqCount = 10
AcqCount = 10
Command
Response
>get AcqCount
AcqCount = 10
AcqC1Count
9800 |
9780
|
8780
|
9640
|
9774
AcqC1Count is an alias for the AcqCount command. The ALR-9800, being a
multi-protocol reader, must explicitly call out the specific air protocol to which
each acquisition parameter applies.
AcqC1Count Examples
Command
Response
>get AcqC1Count
AcqC1Count = 1
Command
Response
>set AcqC1Count = 5
AcqC1Count = 5
AcqSleepCount
9800 | 9780 | 8780 | 9640 |
9774
AcqSleepCount takes a single integer parameter between 0 and 255. It is the
number of Sleep commands that are issued after the reader scans for tags in
each Class1 / Gen1 acquisition cycle. The default value for AcqSleepCount is 1.
The Sleeps act on the tags that were read in the current acquisition cycle.
For example, if AcqSleepCount is set to 5, then five Sleep commands are issued
during each acquisition cycle.
NOTE: Changes made with this command will take effect immediately.
AcqSleepCount Examples
Command
Response
>set AcqSleepCount = 5
AcqSleepCount = 5
Command
Response
>get AcqSleepCount
AcqSleepCount = 5