AGC

Support

D/N Mode

Auto / Color/ BW (Black and White)

White Balance

ATW / MWB

BLC

Support

Digital Wide Dynamic Range (DWDR)

Support

Language

English. Chinese

Functions

Brightness, Sharpness, Digital noise reduction, Mirror, Smart IR

General

Operating Conditions

-40°F 

~

 140°F (-40°C 

~

 60°C), Humidity 90% or less (non-condensing)

Power Supply

12 Vdc ±25%

Power Consumption

Max. 9 W

Protection Level

IP67

Material

Metal

IR Range

Up to 135 ft (40 m)

Communication

Up the coax (HD-TVI output)

Dimensions

5.29” × 4.88” × 4.38” (34.3 mm × 123.9 mm × 110.1 mm)

Weight

1.57 lb (750 g) approx. 

Cleaning

Clean the camera dome with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time. 

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

Troubleshooting

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 

- Check the video signal cable connection to the monitor. 

- Check HD-TVI DVR camera settings to verify the video resolution mode of the 

   camera and HD-TVI DVR match

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.

- Adjust the monitor controls, if necessary. 

- If the camera is facing a very strong light, change the camera position.

- Adjust the lens focus.

The screen is dark.

- Adjust the contrast control of the monitor.

- If you have an intermediate device, set the impedance (75 Ω /Hi-Z)  

   properly, and check the cable connections.

The camera is not working properly and 

the surface of the camera is hot.

- Verify that the camera is correctly connected to an appropriate regulated  

   power source.

The image on the monitor flickers

- Make sure that the camera isn’t facing direct sunlight or fluorescent light.  

   If necessary,change the camera position.

Summary of Contents for ALI-TS2015R

Page 1: ...drop cable 2 Drill holes for the screws that anchor the base to the ceiling The mounting hardware provided is appropriate for most surfaces However depending on the surface materials more appropriate fasteners may be required 3 Drill a 3 4 hole for the drop cable if necessary The drop cable can be routed through the mounting surface or through a cable channel in the mounting plate 4 Route camera v...

Page 2: ...op Open the OSD menu The On Screen Display OSD provides configuration options for refining the performance of the camera It also can be used to block sensitive portions in the field of view Privacy You can open the OSD menu system from either an ALIBI HD TVI DVR Live View display or through remote login to the ALIBI recorder Opening the OSD Menu through the HD TVI DVR To open the OSD menu on the H...

Page 3: ...ut Iris OPEN Set parameter value or open sub menu Iris CLOSE Cancel change of parameter OSD Definitions On screen Display OSD menus After the camera is installed on a compatible recorder you can open the OSD menu clicking the PTZ Control icon on the Quick Setting Toolbar or calling a Preset95 function To navigate the OSD menu and select options Move the cursor up down to select the menu item Move ...

Page 4: ...IN value from 1 to 255 to adjust the shades of red blue color of the image DAY NIGHT Color B W and AUTO are selectable for DAY and NIGHT switches COLOR The image is colored in day mode all the time B W The image is black and white all the time and the IR LED turns on in the low light conditions AUTO Automatically switch COLOR or BW Black and White according to actual scene brightness You can turn ...

Page 5: ... These may cause damage to the surface over time CAUTION Donotusebenzene thinnerorotherchemicalproductsonthecameraassembly thesemay dissolvethepaintandpromotedamageofthesurfaces Beforeusinganychemicalproduct carefullyfollowtheaccompanyinginstructions Troubleshooting Problem Possible Cause Nothing appears on the screen Check the power connection Check the video signal cable connection to the monito...

Reviews: