: Set the Zoom In function to 100, 90, .. 50 as needed. 50 is the highest zoom in. 

 

Lamp

: Set the Lamp option to Off, On, or Auto. If you select On or Auto, open the submenu to 

set the brightness (1 .. 5).  

• 

RESET

: Select reset to set all parameter values to the factory default setting.  

• 

SAVE & EXIT

: Select Save & Exit to close the OSD menu.  

Specifications

Camera

Image Sensor

1.27 Mega Progressive Scan CMOS

Signal system

PAL/NTSC

Effective Pixels

1305 (H) * 977 (V)

Min. Illumination

0.001 Lux @ (F1.2, AGC ON),0 Lux with white light

Shutter Time

1/100 s to 1/50,000 s

Lens

6 ~ 22 mm motorized VF lens

Lens Mount

Φ14

Day & Night

Color

Synchronization

Internal synchronization

Video Frame Rate

720p @ 25 fps / 720p @ 30 fps

HD Video Output

1 turbo HD output

CVBS Video Output

1 Vp-p composite output(75 Ω / BNC)

S/N Ratio

> 62 dB

Menu

Auto Gain

Low/Middle/High/Off

D/N Mode

Color

White Balance

Auto/Manual

Private Mask

On/Off, maximum 8 zones

Motion Detection

On/Off, maximum 4 zones

Exposure Mode

Global Exposure/Digital WDR

3D Noise Reduction

Low/Middle/High/Off

Language

English/Chinese

Function

Contrast/Sharpness/Saturation/Mirror/Digital zoom

White Light Control

On / Off / 1-5 adjustable level

General

Operating Conditions

-40 °F ~ 140 °F (-40°C ~ 60°C ) 

Humidity 90% or less (non-condensing)

Power Supply

12 Vdc ±15% 

Power Consumption

Max. 5W

Protection Level

IP66

Light Distance

98 ~ 131 ft (30 ~ 40 m)

Communication

Up the coax 

Protocol: Pelco-C (CVBS output), HD-TVI output)

Dimensions

5.28 × 4.57 × 11.54 in. (134 × 116 × 293 mm)

Weight

24.7 oz (700 g)

CLEANING

Clean the camera lens with an approved glass cleaning solution and a lint free cloth. 

• 

Dust can be removed from the unit by wiping it with a soft damp cloth. To remove stains, gently rub 
the surface with a soft cloth moistened with a mild detergent solution, then rinse and dry it with a 
soft cloth.

• 

Remove all foreign particles, such as plastic or rubber materials, attached to the camera housing. 
These may cause damage to the surface over time.  

CAUTION

Do not use benzene, thinner or other chemical products on the camera assembly; these may 
dissolve the paint and promote damage of the surfaces. Before using any chemical product, 
carefully follow the accompanying instructions.

TROUBLESHOOTING

Problem

Possible Cause

Nothing appears on the screen 

- Check the power connection. 

- Check the video signal cable connection to the monitor. 

The video image is dim or not clear.

- If the camera lens is dirty, clean it with a soft, clean cloth.

- Adjust the monitor controls, if necessary. 

- If the camera is facing a very strong light, change the camera position.

- Adjust the lens focus.

The screen is dark.

- Adjust the contrast control of the monitor.

- If you have an intermediate device, set the impedance (75 Ω /Hi-Z)  

   properly, and check the cable connections.

The camera is not working properly and 

the surface of the camera is hot.

- Verify that the camera is correctly connected to an appropriate regulated  

   power source.

The image on the monitor flickers

- Make sure that the camera isn’t facing direct sunlight or fluorescent light.  

   If necessary,change the camera position.

Summary of Contents for ALI-BC1720LPC

Page 1: ...the CVBS monitor impedance switch to 75 Ω Camera drop cable The camera drop cable includes two connectors Video BNC connectors For transmission of the video signal across a coax 75 Ω extension cable BNC connectors are labeled for the signal type Connect the TVI drop cable to an HD TVI hybrid video recorder interface and the CVBS drop cable to an NTSC monitor or a CVBS recorder video input Power co...

Page 2: ... s performance in your surveillance venue SETUP 3DNR Brightness Mirror Contrast Shutter Color Gain Sharpness Sensitivity Area 1 8 Detection Masking Zoom In Lamp AGC AE Mode Function Save Exit Reset AE WB Video Setting Focus Language Video Standard Main Menu Color Area 1 8 OSD menu tree OSD menus are only accessible through the ALIBI Digital Video Recorder DVR or Hybrid Video Recorder HVR it is con...

Page 3: ...Manual click Iris and then set the RGAIN red and BGAIN blue levels VIDEO SETTING In the Video Setting submenu you can set the following Contrast Set the contrast level from 1 10 for best image Sharpness Set the sharpness level from 1 10 for best image Color Gain Set the color gain level from 1 10 for best image 3DNR Select either High Middle Low or off for the best level of noise reduction Mirror ...

Page 4: ...e coax Protocol Pelco C CVBS output HD TVI output Dimensions 5 28 4 57 11 54 in 134 116 293 mm Weight 24 7 oz 700 g CLEANING Clean the camera lens with an approved glass cleaning solution and a lint free cloth Dust can be removed from the unit by wiping it with a soft damp cloth To remove stains gently rub the surface with a soft cloth moistened with a mild detergent solution then rinse and dry it...

Reviews: